Key result
Phantom shocks in implantable cardioverter defibrillator recipients were reported to be indistinguishable from objective shocks and were associated with elevated levels of social desirability and depression.
Why the study?
What are the psychosocial correlates and subjective experiences of phantom shocks compared to objective shocks in ICD patients?
Case-Control (n=17)
No
What are the psychosocial correlates and subjective experiences of phantom shocks compared to objective shocks in ICD patients?
Phantom shocks in ICD patients are associated with significant emotional distress, including elevated trauma and anxiety levels comparable to or differing in specific domains from those experiencing objective shocks.
Answers are grounded in this paper and cite their sources.
Supports psychosocial screening in ICD patients reporting shocks; hypothesis-generating and needs prospective validation.
BACKGROUND: Implantable cardioverter defibrillator recipients sometimes report "phantom shocks" (PSs), defined as a reported shock lacking objective evidence. The aim of this study was to describe the subjective experience of PSs and their psychosocial correlates using a mixed methods approach. METHODS: PS participants were matched on sex and age with individuals who received objective shocks only (OSO). Participants were interviewed and completed measures of posttraumatic stress disorder (PTSD Checklist-Civilian Version), depression and anxiety (Hospital Anxiety and Depression Scale), disease-specific distress (Cardiac Anxiety Questionnaire-CAQ), and social desirability (Socially Desirable Response Set-SDRS). Interviews were analyzed using interpretative phenomenological analysis (IPA). RESULTS: Seventeen male patients participated (PS: n = 9; OSO: n = 8). Three themes emerged from IPA: (1) PS as a somatic experience, (2) the emotional impact of PSs, and (3) searching for meaning. Quantitative analyses showed that both groups exhibited elevated trauma and anxiety levels. Effect size differences (ESD) suggested a medium ESD on depression (P = 0.176, ηp (2) = 0.118) and PTSD (avoidance: P = 0.383, ηp (2) = 0.055, numbing: P = 0.311, ηp (2) = 0.068), and a large ESD on SDRS (P = 0.081, ηp (2) = 0.189), where PS participants, comparatively, exhibited elevated levels. A medium ESD was detected on CAQ-fear (P = 0.237, ηp (2) = 0.092) where OSO participants exhibited greater heart-focused worry. CONCLUSION: The qualitative and quantitative findings of this mixed method study show convergence in terms of the emotional factors associated with the experience of PSs. PSs are often reported to be indistinguishable from objective shocks, evoking alarm, frustration, and confusion, forcing the individual to face the uncertainties of what to them is a novel and confusing experience.
No takes yet. Share an insight, caveat, or question.
Bilanovic et al. (2013) conducted a case-control in Phantom shocks in implantable cardioverter defibrillator (ICD) recipients (n=17). Phantom shocks vs. Objective shocks only was evaluated on Socially Desirable Response Set (SDRS-5) score (ηp2 = 0.189, p=0.081). Phantom shocks in implantable cardioverter defibrillator recipients were reported to be indistinguishable from objective shocks and were associated with elevated levels of social desirability and depression.
Synapse has enriched 10 related papers. Consider them for comparative context: