Why the study?
Does the time point of zero crossing after initial negative velocities in TDI and speckle tracking accurately represent aortic valve closure in infarcted ventricles and at high heart rates compared to B-mode imaging?
Does the time point of zero crossing after initial negative velocities in TDI and speckle tracking accurately represent aortic valve closure in infarcted ventricles and at high heart rates compared to B-mode imaging?
The time point of zero crossing after initial negative velocities in velocity/time curves is a practical and accurate marker for aortic valve closure at high heart rates and in infarcted ventricles.
Answers are grounded in this paper and cite their sources.
Supports AVC timing via zero-crossing in TDI/speckle tracking at high rates and post-infarct; leaves open prospective validation before routine adoption.
AIM: To resolve the event in tissue Doppler (TDI)- and speckle tracking-based velocity/time curves that most accurately represent aortic valve closure (AVC) in infarcted ventricles and at high heart rates. METHODS: We studied the timing of AVC in 13 patients with myocardial infarction and in 8 patients at peak dobutamine stress echo. An acquisition setup for recording alternating B-mode and TDI image frames was used to achieve the same frame rate in both cases (mean 136.7 frames per second [FPS] for infarcted ventricles, mean 136.9 FPS for high heart rates). The reference method was visual assessment of AVC in the high frame rate narrow sector B-mode images of the aortic valve. RESULTS: The initial negative velocities after ejection in the velocity/time curves occurred before AVC, 44.9 +/- 21.0 msec before the reference in the high heart rate material, and 25.2 +/- 15.2 msec before the reference in the infarction material. Using this time point as a marker for AVC may cause inaccuracies when estimating end-systolic strain. A more accurate but still a practical marker for AVC was the time point of zero crossing after the initial negative velocities after ejection, 5.4 +/- 15.3 msec before the reference in high heart rates and 8.2 +/- 12.9 msec after the reference in the infarction material. CONCLUSION: The suggested marker of AVC at high heart rate and in infarcted ventricles was the time point of zero crossing after the initial negative velocities after ejection in velocity/time curves.
No takes yet. Share an insight, caveat, or question.
Aase et al. (2010) studied this question.