Key result
Abnormal D-dimer levels in patients with mechanical heart valve replacement on oral anticoagulation were associated with a higher risk of thrombotic events.
Why the study?
Adverse events may still occur after mechanical heart valve replacement despite oral anticoagulation, prompting investigation into whether D-dimer can predict clinical events.
Does abnormal D-dimer predict thrombotic events and all-cause deaths in post-MHVR patients on oral anticoagulation therapy?
Cohort (n=718)
No
Does abnormal D-dimer predict thrombotic events and all-cause deaths in post-MHVR patients on oral anticoagulation therapy?
Abnormal D-dimer levels measured 3 months post-MHVR independently predict a higher risk of thrombotic events and all-cause mortality during oral anticoagulation therapy.
Answers are grounded in this paper and cite their sources.
May identify higher-risk mechanical valve patients for closer monitoring; leaves open whether D-dimer-guided interventions reduce events.
Mechanical heart valve replacement (MHVR) entails lifetime oral anticoagulation to eliminate thrombosis. However, adverse events may still occur despite proper anticoagulation therapy. In this study, we investigated whether D-dimer can predict the clinical events in post-MHVR patients during oral anticoagulation therapy.This was a single-center, prospective study. In all, 772 patients who underwent MHVR in the Wuhan Asia Heart Hospital from January 2013 to May 2014 were screened. Patients were assigned to the abnormal D-dimer group and the normal D-dimer group according to the D-dimer levels measured 3 months after the beginning of the oral anticoagulation therapy regime. All patients were followed up for 24 months or until the observation of the endpoints, which included thrombotic events, bleeding events, and all-cause deaths.A total of 718 patients were included in the analysis: 91 had abnormal D-dimer levels, and 627 had normal D-dimer levels. In all, 53 events were observed during 24 months. Compared with the normal D-dimer group, patients with abnormal D-dimer levels had a higher incidence of thrombotic events (10 versus 14; hazard ratio (HR): 5.36; 95% confidence interval (CI): 2.38-12.1; P < 0.001), all-cause mortality (8 versus 13; HR: 4.65; 95% CI: 1.93-11.2; P < 0.001), and a higher incidence of total events (16 versus 37; HR: 3.26; 95% CI: 1.81-5.86; P < 0.001). No significant difference was observed in bleeding events (2 versus 21; HR: 0.72; 95% CI: 0.17-3.07; P = 0.66).D-dimer may be a useful marker to predict thrombotic events and all-cause deaths in post-MHVR patients during oral anticoagulation therapy (ClinicalTrials.gov; NCT01996657).
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2019) conducted a cohort in Mechanical heart valve replacement (n=718). Abnormal D-dimer levels vs. Normal D-dimer levels was evaluated on Thrombotic events (HR 5.36, 95% CI 2.38-12.1, p=<0.001). Abnormal D-dimer levels in patients with mechanical heart valve replacement on oral anticoagulation were associated with a higher risk of thrombotic events.
Synapse has enriched 10 related papers. Consider them for comparative context: