Why the study?
Does temporary interruption of long-term cardiac resynchronization therapy worsen haemodynamic parameters and mitral regurgitation in patients with LV dysfunction and heart failure?
Does temporary interruption of long-term cardiac resynchronization therapy worsen haemodynamic parameters and mitral regurgitation in patients with LV dysfunction and heart failure?
Temporary cessation of long-term biventricular pacing leads to rapid deterioration in LV systolic performance and worsening of functional mitral regurgitation, supporting the need for indefinite CRT maintenance.
Answers are grounded in this paper and cite their sources.
CRT withdrawal linked to acute LV deterioration and MR worsening; supports uninterrupted pacing but leaves open long-term outcome benefits.
AIMS: Cardiac resynchronization therapy (CRT) utilizing biventricular pacing (BVP) is a promising treatment modality for symptomatic patients with chronic left ventricular (LV) systolic dysfunction and intraventricular conduction delay. Clinical studies have shown short-term improvement in contractile function and mid-term improvement in clinical status with CRT. The objective of this study was to evaluate the haemodynamic consequences of temporary interruption of CRT after long-term stimulation. METHODS AND RESULTS: Twenty patients (16 men, 4 women) with LV dysfunction and New York Heart Association class III or IV heart failure, despite optimal medical therapy and a QRS interval of at least 120 ms, received a transvenous BVP system at the age of 66 (interquartile range, 61-69). Patients were studied after a median duration of 427 days (interquartile range, 281-563) of continuous CRT and again 72 h after cessation of BVP. Withdrawal of CRT resulted in a significant decline in maximal rate of LV systolic pressure rise from 711 mmHg/s (interquartile range, 640-816) to 442 mmHg/s (interquartile range, 389-582) (P=0.0001) and increases in mitral effective regurgitant orifice area from 4.8 mm(2) (interquartile range, 0.0-7.8) to 9.1 mm(2) (interquartile range, 5.7-13.3) (P=0.0001), mitral regurgitant volume from 7.8 mL (interquartile range, 0.0-11.5) to 16.0 mL (interquartile range, 10.7-20.8) (P=0.0001) and fraction from 13.8% (interquartile range, 0.0-19.2) to 27.7% (interquartile range, 14.6-34.0) (P=0.0002) determined by Doppler echocardiography. CONCLUSION: Cessation of long-term BVP leads to a decline in LV systolic performance and an increase in functional mitral regurgitation. These results indicate a sustained benefit of long-term CRT and support the notion to maintain CRT indefinitely.
No takes yet. Share an insight, caveat, or question.
Brandt et al. (2005) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: