Why the study?
Does worsening of tricuspid regurgitation after ICD implantation worsen clinical outcomes in patients with ARVC?
Cohort (n=35)
No
Does worsening of tricuspid regurgitation after ICD implantation worsen clinical outcomes in patients with ARVC?
Answers are grounded in this paper and cite their sources.
In a small cohort of patients with ARVC, worsening of tricuspid regurgitation after ICD implantation was common but was not significantly associated with worse clinical outcomes.
Introduction. The problem of lead-induced tricuspid regurgitation (LITR) in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC) is poorly investigated. Patients with high risk of adverse outcome usually receive implantable cardioverter-defibrillator (ICD) as a prevention of sudden cardiac death (SCD). Unfortunately, the insertion of ICD into the right ventricle is supposed to exacerbate tricuspid regurgitation.
No takes yet. Share an insight, caveat, or question.
Poślednik et al. (2016) conducted a cohort in Arrhythmogenic right ventricular cardiomyopathy (ARVC) (n=35). Worsening of tricuspid regurgitation after ICD implantation vs. No worsening of tricuspid regurgitation was evaluated on Cardiovascular death or orthotopic heart transplantation (OHT) (p=not significant).