Highlights the risk of severe tricuspid valve injury as a major complication during the extraction of recalled right ventricular ICD leads.
Answers are grounded in this paper and cite their sources.
Single-case report of ICD extraction in severe cardiomyopathy; leaves open procedural safety and generalizability pending larger studies.
A 67-YEAR-OLD MALE (height 183 cm, weight 100 kg) with a history of anterior myocardial infarction and cardiomyopathy (estimated ejection fraction of 20%-25%) presented for implantable cardioverter-defibrillator (ICD) lead extraction and single-chamber ICD reimplantation. At the time of presentation, his device was a single-chamber Medtronic Virtuoso ICD (Medtronic, Dublin, Ireland), which was implanted in 2007 for inducible ventricular tachycardia. The extraction was planned because the existing right ventricular (RV) Fidelis lead (Medtronic) had been placed on Food and Drug Administration advisory and the device battery was nearing elective replacement indications. His preoperative transthoracic echocardiogram showed severe regional left ventricular (LV) systolic dysfunction, with akinesis of the septum and severe hypokinesis of the mid-anterior wall and all distal LV segments.
No takes yet. Share an insight, caveat, or question.
Hai et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: