Dual myocardial scintigraphy visualizes extensive biventricular necrosis in a patient with NSTEMI.
Case Report (n=1)
No
This case highlights the utility of dual SPECT imaging with 99mTc-PYP and thallium-201 for identifying extensive subendocardial left ventricular and right ventricular myocardial damage in acute myocardial infarction with severe multivessel disease when the culprit lesion and extent of injury are undetermined.
Answers are grounded in this paper and cite their sources.
May aid damage mapping in complex NSTEMI when culprit unclear; leaves open routine use pending prospective data.
Technetium-99m-pyrophosphate (99mTc-PYP) has been used, in combination with thallium-201, to estimate the site and extent of myocardial infarcts. We report a case of acute myocardial infarction with severe coronary disease in which the distribution of 99mTc-PYP was extensive. A 78-year-old man presented with dyspnea, and a diagnosis of non-ST-segment elevation acute myocardial infarction was made. Emergency coronary angiography revealed total occlusion of the proximal portion of the right coronary artery and left circumflex coronary artery with collateral flow from the left anterior descending coronary artery, which also had severe stenoses. Given his comorbidities and preferences, subsequent angioplasty was waived. Dual myocardial scintigraphic imaging, which was performed four days after admission, demonstrated slightly reduced thallium-201 uptake in the inferior wall and apex, whereas 99mTc-PYP was positive in the entire left ventricular subendocardial region and the free wall of the right ventricle. His clinical course was uneventful with conservative treatment and the patient was discharged 20 days after admission in a stable condition.
No takes yet. Share an insight, caveat, or question.
Kawamata et al. (2020) conducted a case report in Non-ST-segment elevation acute myocardial infarction with severe multivessel coronary artery disease and heart failure (n=1). Dual myocardial scintigraphic imaging with technetium-99m-pyrophosphate (99mTc-PYP) and thallium-201 was evaluated on Localization and extent of myocardial infarction/damage on dual SPECT imaging. Dual myocardial scintigraphy with 99mTc-PYP and thallium-201 demonstrated extensive tracer uptake throughout the entire left ventricular subendocardium and right ventricular free wall in a 78-year-old man with NSTEMI.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: