Rb86 clearance can be used to estimate coronary blood flow without requiring cardiac vein catheterization, with acceptable error at lower flow rates.
Answers are grounded in this paper and cite their sources.
May support Rb86-based flow estimation across ventricles in animal models; leaves open human validation without catheterization.
The rate of myocardial clearance of Rb 86 from arterial blood and the rate of coronary blood flow were studied simultaneously during a 10-min period of isotope infusion in dogs. In order to measure blood flow to the right and left ventricles separately using the Fick principle, venous blood was obtained from an anterior cardiac vein and from the coronary sinus. The relationship of myocardial blood flow and Rb 86 clearance was not detectably different in the right and left ventricles. The percentage error in predicting flow from clearance rose as the values increased. At rates of flow below 6 ml/g 10 min the mean error was 4.7%. From 6 to 12 ml/g 10 min the mean error was 10.0% in controls and 14.4% in a group with pulmonary embolism or obstruction of the pulmonary artery. Since the clearance technique does not require catheterization of a cardiac vein, this method can be used to study coronary blood flow under conditions approximating the undisturbed state.
No takes yet. Share an insight, caveat, or question.
Love et al. (1963) studied this question.