Why the study?
Rope jumping is often overlooked for cardiorespiratory endurance. The study aimed to evaluate the metabolic cost and relative intensity of repetitive jumping on the Digi-Jump machine compared with literature on jump rope exercise and treadmill VO2max.
What is the relative intensity and metabolic cost of repetitive jumping on the Digi-Jump machine compared to maximal treadmill exercise in healthy participants?
What is the relative intensity and metabolic cost of repetitive jumping on the Digi-Jump machine compared to maximal treadmill exercise in healthy participants?
Repetitive jumping on the Digi-Jump machine is a strenuous activity that elicits a high percentage of maximal heart rate and oxygen uptake, similar to jumping rope.
Provides preliminary metabolic data on Digi-Jump rope jumping; leaves open its role in aerobic training pending larger trials.
Cardiorespiratory endurance is an important element of aerobic fitness, particularly in weight management and reducing risk for cardiovascular disease. While there are numerous options for aerobic exercise, rope jumping is often overlooked. In addition to regular exercise and a healthy diet, the American Heart Association strongly recommends rope jumping. The first purpose of this study was to determine the steady state metabolic cost of repetitive jumping on the Digi-Jump machine to evaluate whether exercise on this device is more or less strenuous than similar exercise with a jump rope, as demonstrated in previous literature. A second purpose was to determine the relative intensity of exercise on the Digi-Jump by comparing to VO2max as measured on a treadmill. Twenty-seven participants completed two trials, one jumping trial at a rate of 120 jumps per minute with the jumping height set at 0.5 inch for 5-min on the Digi-Jump, and one graded exercise test using the Bruce protocol. Oxygen uptake (VO2), heart rate (HR), respiratory exchange ratio (RER), and rating of perceived exertion (RPE) were measured each minute during each trial. Results of this study indicated that steady state VO2 during the 5-min jump test was reached at the 3rd min. Steady state variables during the jumping trial expressed as percentage of max were as follows: VO2 was 57.1% of VO2max; HR was 80.9% of HRmax; RER was 86%of RERmax; and RPE was 75.2% of RPEmax. These data indicate that repetitive jumping is a strenuous activity and similar in intensity to jumping rope, even if the trial is done on the Digi-Jump machine with free-swinging arms and without a jump rope.
No takes yet. Share an insight, caveat, or question.
Navalta et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: