Key result
The free-breathing MOLLI sequence and optimized reconstruction method increased the accuracy and reproducibility of free-breathing T1 measurements.
Why the study?
Does a free-breathing MOLLI sequence with optimized reconstruction improve the accuracy and reproducibility of myocardial T1 mapping in healthy volunteers?
Does a free-breathing MOLLI sequence with optimized reconstruction improve the accuracy and reproducibility of myocardial T1 mapping in healthy volunteers?
The FB-MOLLI method provides a robust tool for free-breathing myocardial T1 mapping, which could facilitate acquisition procedures for patients unable to perform voluntary breath-holds.
Answers are grounded in this paper and cite their sources.
May support free-breathing T1 mapping in breath-hold intolerant patients; leaves open validation in clinical populations.
PURPOSE: Of the myocardial T(1) mapping techniques, the modified Look-Locker inversion recovery (MOLLI) sequence is accurate and highly reproducible. The MOLLI sequence requires patients to hold their breath for 17 heartbeats during the scanning process to minimize respiratory motion-related artifacts. However, some patients are unable to hold their breath because of illness or limited breath-hold capacity. This study, therefore, aimed to develop a robust myocardial T(1) mapping method based on the MOLLI sequence for patients unable to perform voluntary breath-holds. METHODS: This study presents a free-breathing MOLLI (FB-MOLLI) sequence and an optimized reconstruction method to allow myocardial T(1) mapping in vivo without breath-hold. Nine healthy volunteers participated in this study after providing institutionally approved consent. The FB-MOLLI sequence acquires 20 images within 29 heartbeats. The reconstruction program employs a two-step automatic image registration technique and an image selection method inspired by the self-gating cardiac imaging method. RESULTS: Results indicate that the proposed reconstruction method increases the accuracy and reproducibility of free-breathing T(1) measurements significantly (p < 0.001). CONCLUSIONS: The FB-MOLLI method provides a robust tool for clinical application in free-breathing myocardial T(1) mapping, and could greatly facilitate acquisition procedures during routine examinations.
No takes yet. Share an insight, caveat, or question.
Tsai et al. (2012) studied Healthy volunteers (n=9). Free-breathing MOLLI (FB-MOLLI) sequence and optimized reconstruction method was evaluated on Accuracy and reproducibility of free-breathing T1 measurements (p=<0.001). The free-breathing MOLLI sequence and optimized reconstruction method increased the accuracy and reproducibility of free-breathing T1 measurements.
Synapse has enriched 10 related papers. Consider them for comparative context: