Key result
A novel parameterized respiratory filter algorithm with a K-band radar sensor demonstrated better Doppler cardiogram extraction performance than conventional methods in the presence of respiration.
Why the study?
Existing techniques for Doppler cardiogram measurement via Doppler radar require subjects to hold their breath to avoid respiratory disturbance.
Does a K-band radar sensor with a parameterized respiratory filter algorithm improve Doppler cardiogram extraction compared to conventional methods?
Does a K-band radar sensor with a parameterized respiratory filter algorithm improve Doppler cardiogram extraction compared to conventional methods?
A novel parameterized respiratory filter algorithm combined with a K-band radar sensor enables accurate, contactless detection of Doppler cardiograms without requiring breath-holding.
Cardiogram is one of the most important factors for health assessment. As a new expression of cardiograms, the Doppler cardiograms (DCGs) detected remotely via Doppler radar sensor (DRS) provide rich details of the heart motion. However, the existing techniques for measurement of DCG requires that the subject holds his/her breath to avoid the disturbance caused by respiration. To realize the accurate detection of DCGs in the presence of respiration, a high-linearityK-band dc-coupled continuous-wave (CW) DRS with digital dc-tuning function was custom-designed and a novel parameterized respiratory filter (PRF) algorithm was proposed to precisely remove the respiratory signal. Both simulation and experimental results show that the proposed PRF algorithm has better DCG extraction performance than the conventional methods. Furthermore, the experimental results in normal and clinical environments show that the grained differential DCG (D-DCG) has promising potential in professional heart rate variability (HRV) analysis and heart diseases diagnosis, which means the proposed DCGs detection has the potential to be a convenient, comfortable, and reliable way for daily and clinical heart health assessment.
No takes yet. Share an insight, caveat, or question.
Dong et al. (2022) studied Heart motion / cardiogram detection. Parameterized respiratory filter (PRF) algorithm with K-band radar sensor vs. Conventional methods was evaluated on Doppler cardiogram extraction performance in the presence of respiration. A novel parameterized respiratory filter algorithm with a K-band radar sensor demonstrated better Doppler cardiogram extraction performance than conventional methods in the presence of respiration.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: