Key result
Defibrillation threshold testing after ICD implantation was associated with increased 30-day heart failure hospitalizations.
Why the study?
Defibrillation threshold testing after ICD implantation has not been shown to improve mortality, and its impact on the burden of heart failure hospitalisations has not been well defined.
Does defibrillation threshold testing increase the burden of heart failure hospitalizations in patients undergoing ICD implantation or generator change?
Cohort (n=501)
Does defibrillation threshold testing increase the burden of heart failure hospitalizations in patients undergoing ICD implantation or generator change?
Defibrillation threshold testing during ICD implantation or generator replacement is associated with a significantly increased risk of heart failure hospitalization at 30 days.
Answers are grounded in this paper and cite their sources.
DT may raise early HF hospitalization risk post-ICD; leaves open whether routine testing should be avoided pending confirmation.
Background: Defibrillation threshold testing (DT) following implantable cardioverter defibrillator (ICD) implantation has not shown to improve mortality. However, the impact of DT on burden of heart failure (HF) hospitalisations has not been well defined.Methods: We studied retrospectively consecutive patients who underwent ICD implantation or generator change between 2008 and 2014. Primary outcome was burden of HF hospitalisations within 30 days following implantation. Secondary outcomes were mortality, stroke, and ICD shock within 30 days and one-year mortality.Results: Three hundred and eleven of 501 patients (62%) were in DT+ group versus 190 (38%) were in DT− group. The percentage of new implantations was higher in DT+ group than in DT− group (69% vs 39%, p < .001) but the distributions of NYHA function classes were similar between two groups. The burden of HF hospitalisations at 30-days was significantly higher in DT+ group than in DT− group (17.4% vs 4.7%, HR 0.842, 95% CI 0.774–0.915, p < .0001). No difference in mortality, stroke or ICD shocks was found between two groups at 30 days and mortality at 1 year.Conclusions: DT after new ICD or generator replacement was associated with increased HF hospitalisation rates at 30 days after ICD implant in a non-trial HF population. However, there was no association between DT and mortality, stroke and ICD shocks at 30 days or mortality at 1 year. The increased burden of HF hospitalisation in this observational study requires validation by randomised studies.
No takes yet. Share an insight, caveat, or question.
Akdemir et al. (2019) conducted a cohort in ICD implantation or generator change (n=501). Defibrillation threshold testing (DT) vs. No defibrillation threshold testing (DT-) was evaluated on Burden of HF hospitalisations within 30 days following implantation (HR 0.842, 95% CI 0.774-0.915, p=<0.0001). Defibrillation threshold testing after ICD implantation was associated with increased 30-day heart failure hospitalizations.
Synapse has enriched 10 related papers. Consider them for comparative context: