Why the study?
Does the automated VWF Activity assay correlate with VWF:RCo for the diagnosis and subtyping of von Willebrand disease?
Does the automated VWF Activity assay correlate with VWF:RCo for the diagnosis and subtyping of von Willebrand disease?
Answers are grounded in this paper and cite their sources.
The automated VWF:Act assay combined with PFA-100 is an effective screening strategy for von Willebrand disease, though VWF:RCo remains the reference for subtype classification.
We evaluated the use of the turbidimetric HemosIL von Willebrand Factor (VWF) Activity assay (VWF:Act) on the STA-R automated coagulometer (Stago, Asnières, France) for the diagnosis of von Willebrand disease (VWD). For this, we prospectively screened 268 patients. As a second part, we retrospectively assayed 111 patients with well-defined VWD subtype. In the first prospective study, we demonstrate that in most cases of VWD, VWF ristocetin cofactor activity (VWF:RCo) and VWF:Act are highly correlated but that they both cannot be considered a good screening assay when used alone, since they could miss about 25% of VWF abnormalities. However, the association of VWF:Act analysis and the Platelet Function Analyzer-100 (PFA-100) test constitutes an excellent screening strategy. In our second retrospective study concerning VWD subtypes, VWF:RCo and VWF:Act were well correlated but could be very discrepant, especially for some cases of type 2M VWD. We consider that VWF:RCo remains the "reference assay" for VWD subtype classification.
No takes yet. Share an insight, caveat, or question.
Trossaërt et al. (2010) studied this question.