Key result
The Cvpilot deep learning system significantly reduced the total time required for pre-TAVR computed tomography angiography evaluation to 1.0 minute compared to 17.7 minutes with the 3mensio system.
Why the study?
To explore the practicability of the novel deep learning Cvpilot system in the automatic segmentation and technical evaluation of the aortic root before TAVR.
Does the Cvpilot deep learning system provide accurate and efficient segmentation and measurement of pre-TAVR CTA scans compared to conventional software in patients undergoing TAVR?
Observational (n=154)
No
Does the Cvpilot deep learning system provide accurate and efficient segmentation and measurement of pre-TAVR CTA scans compared to conventional software in patients undergoing TAVR?
Absolute Event Rate: 1% vs 17.7%
p-value: p=<0.001
The AI-driven Cvpilot system provides accurate and significantly faster pre-TAVR aortic root measurements compared to conventional software, improving workflow efficiency.
May expedite pre-TAVR CTA workflows; leaves open prospective validation before routine adoption.
Objective: The goal of this study was to compare the computed tomography angiography scans of the segmentation results from the Cvpilot, 3mensio, and Volume Viewer systems to explore the practicability of the Cvpilot system in the automatic segmentation and technical evaluation of the aortic root before transcatheter aortic valve replacement (TAVR). Design: A total of 154 patients who underwent TAVR at our center from January 2022 to May 2023 were enrolled, and their computed tomography angiography images were analyzed using the Cvpilot, 3mensio, and Volume Viewer systems, respectively. Setting: Not applicable. Participants: Not applicable. Main outcome measures: The reconstructed computed tomography angiography images were evaluated by experts, and the measurements of the aortic roots were analyzed statistically. Results: Compared with the 3mensio system, 92.2% of patients ( n = 142) evaluated with the Cvpilot system reached grade A, 5.2% of patients ( n = 8) reached grade B, and 2.6% of patients ( n = 4) reached grade C. Compared with the Volume Viewer system, 90.9% of patients ( n = 140) evaluated with the Cvpilot system achieved grade A, 7.1% of patients ( n = 11) achieved grade B, and 2.0% of patients ( n = 3) achieved grade C. Furthermore, there was no significant difference among the measurement results of the Cvpilot, 3mensio, and Volume Viewer systems (all p > 0.05). Conclusion: Overall, the Cvpilot system is effective and reliable. It can accurately complete the segmentation and the measurement of aortic root structures, thereby effectively improving the measurement quality before TAVR. Trial registration: Not applicable.
No takes yet. Share an insight, caveat, or question.
Jin et al. (2025) conducted an observational in Aortic stenosis (n=154). Cvpilot system vs. 3mensio and Volume Viewer systems was evaluated on Total time for measurement evaluation (p=<0.001). The Cvpilot deep learning system significantly reduced the total time required for pre-TAVR computed tomography angiography evaluation to 1.0 minute compared to 17.7 minutes with the 3mensio system.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: