Key result
Percutaneous device closure of atrial septal defect significantly decreased left atrial systolic longitudinal strain (mean difference -14.43%) compared to baseline, indicating impaired left atrial reservoir function.
Why the study?
Percutaneous occlusion of ASD has become a standard therapeutic strategy, but little is known about subsequent left atrial function.
Does percutaneous device closure of ASD compared to surgical repair affect left atrial function measured by 2D speckle tracking echocardiography in children?
Observational (n=56)
No
Does percutaneous device closure of ASD compared to surgical repair affect left atrial function measured by 2D speckle tracking echocardiography in children?
Mean Difference: -14.43 (95% CI -17.88–-10.99)
Absolute Event Rate: 28% vs 43%
p-value: p=<0.0001
Percutaneous occlusion of ASD in children acutely decreases left atrial strain compared to surgical repair, with larger devices causing greater impairment of atrial function.
Percutaneous occlusion of atrial septal defect (ASD) has recently become a standard therapeutic strategy, but little is known about left atrial (LA) function thereafter. The present study aimed to determine LA function in 43 children with ASD and 13 controls based on LA strain measured by two-dimensional echocardiographic speckle tracking (2DE-ST). Among these children, 12 underwent surgery (ASD-S), 31 had device closure (ASD-D), and 13 were included as controls. LA strain was significantly decreased after ASD-D but was not significantly altered after ASD-S, indicating that percutaneous occlusion of an ASD might decrease LA function. Furthermore, the size of the ASD device negatively correlated with LA strain. These results imply that ASD occlusion devices negatively influence LA function and might be important when decided therapeutic strategies for ASD. LA strain measured by 2DE-ST should become a good indicator of LA function after ASD treatment in children.
No takes yet. Share an insight, caveat, or question.
Suzuki et al. (2020) conducted an observational in Atrial septal defect (n=56). Percutaneous occlusion of atrial septal defect vs. Baseline (pre-procedure) and surgical repair was evaluated on Left atrial systolic longitudinal strain of the free wall (LSs-FW) (MD -14.43, 95% CI -17.88 to -10.99, p=<0.0001). Percutaneous device closure of atrial septal defect significantly decreased left atrial systolic longitudinal strain (mean difference -14.43%) compared to baseline, indicating impaired left atrial reservoir function.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: