Why the study?
Does high resolution real time ultrasound accurately identify carotid bifurcation plaques compared to carotid arteriography in patients with transient ischemic attacks?
Does high resolution real time ultrasound accurately identify carotid bifurcation plaques compared to carotid arteriography in patients with transient ischemic attacks?
High-resolution real-time ultrasound can visualize the carotid bifurcation and identify plaques with reasonable accuracy compared to arteriography.
Answers are grounded in this paper and cite their sources.
Ultrasound may aid noninvasive plaque detection in TIA; leaves open validation as arteriography alternative in prospective studies.
We have been using a high resolution real time ultrasound mechanical sector scanner to visualize the carotid bifurcation. Twenty-six patients were studied before carotid arteriography for transient ischemic attacks. One bifurcation was not adequately visualized. Of the remaining 51, plaques were identified correctly in 29; absence of plaques was identified correctly in 15; small plaques were demonstrated by ultrasound in two that did not appear on the arteriogram; and four small plaques and one significant stenosis were not identified by ultrasound.
No takes yet. Share an insight, caveat, or question.
Cooperberg et al. (1979) studied this question.