Key result
Renovascular hypertension reduces angiotensin II-induced aortic contraction by ~55% in denuded rat vessels.
Why the study?
Abnormal activation of the AT1 receptor contributes to renovascular hypertension, but the underlying cellular signaling for AT1 receptor activation by Ang II in this setting required evaluation.
Does renovascular hypertension (2K-1C model) impair angiotensin II-induced aortic contraction and alter AT1 receptor downstream signaling compared to normotensive controls (2K) in rats?
Does renovascular hypertension (2K-1C model) impair angiotensin II-induced aortic contraction and alter AT1 receptor downstream signaling compared to normotensive controls (2K) in rats?
In a rat model of renovascular hypertension (2K-1C), chronic elevation of circulating angiotensin II is associated with impaired angiotensin II-induced vascular smooth muscle contraction despite increased AT1 receptor expression, likely driven by receptor desensitization and reduced IP3 receptor phosphorylation.
Answers are grounded in this paper and cite their sources.
May indicate AT1 desensitization in renovascular hypertension; leaves open translation to human vascular dysfunction.
Renin-angiotensin system plays a critical role in blood pressure control, and the abnormal activation of the AT1 receptor contributes to the development of renovascular hypertension. This study aimed to evaluate the underlying cellular signaling for AT1 receptor activation by Ang II and to compare this mechanism between aortas from 2K-1C and 2K rats. Effects of antagonists and inhibitors were investigated on Ang II-induced contractions in denuded or intact-endothelium aortas. The AT1 receptor antagonist abolished Ang II-induced contraction in 2K-1C and 2K rat aortas, while AT2 and Mas receptors antagonists had no effect. Endothelial nitric oxide synthase inhibition increased the maximal effect (Emax) of Ang II in 2K, which was not changed in 2K-1C aortas. It was associated with lower eNOS mRNA levels in 2K-1C. Endothelium removal increased the Emax of Ang II in 2K-1C and mainly in 2K rat aortas. Nox and COX inhibition did not alter Ang II-induced contraction in 2K and 2K-1C rat aortas. However, AT1 expression was higher in 2K-1C compared to 2K rat aortic rings, whereas expression of phosphorylated (active) IP3 receptors was lower in 2K-1C than in 2K rats. These results demonstrate that endothelium removal impairs Ang II-stimulated contraction in the aorta of 2K-1C rats, which is associated with the reduction of IP3 receptor phosphorylation and activation. In addition, eNOS plays a critical role in Ang II-induced contraction in 2K rat aortas. It is possible that the high Ang II plasma levels could desensitize AT1 receptor in 2K-1C rats, leading to impaired IP3 receptors activation.
No takes yet. Share an insight, caveat, or question.
Fahning et al. (2024) studied Renovascular hypertension (2K-1C rat model). Two-kidney, one-clip (2K-1C) renovascular hypertension and ex vivo Angiotensin II stimulation vs. Normotensive sham-operated two-kidney (2K) rats was evaluated on Angiotensin II-induced maximum contraction (Emax) in endothelium-denuded (E-) thoracic aortic rings (p=<0.05). Angiotensin II-induced maximal contraction in endothelium-denuded aortas was significantly lower in 2K-1C hypertensive rats than in 2K normotensive rats (Emax 0.74 vs 1.64 g, P<0.05).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: