Intraoperative tissue Doppler imaging has significant limitations, including angle dependence, noise, and complex interpretation, which may limit its practical utility for cardiac anesthesiologists in the operating room.
In the operating room (OR), two dimensional imaging is an important assessment modality of cardiac function as we can visually ascertain the size of the ventricles as well as the direction and velocity with which the walls move. Flow Doppler adds information on how the heart handles the blood volume as well as valve function. We have been taught to evaluate heart performance through fractions of volume, such as ejection fraction, or surface areas, such as fractional areas of change. We inspect wall motion. Although these methods are not perfect, we are very comfortable with them as we have abundant experience and patient context. Any future technology will invariably be compared to these benchmarks. In the Core Review article “Intraoperative tissue Doppler imaging is a valuable addition to the cardiac anesthesiologist’s armamentarium,”1 Dr. Skubas provided a detailed outline of the usefulness of Tissue Doppler (TD). We are left with the anticipation that this will usher in a new era of fast and reliable assessments of systolic and diastolic function as well as ischemia. But, can we put the added information in its proper context and is it useful in the OR, when under-anesthesia conditions can change frequently and rapidly? Most importantly, do we appreciate and understand the limitations of this novel technology? Do myocardial and annular velocities always represent myocardial motion? The Doppler signal source and sampling site are fixed. Velocity and direction assessments may be affected by translation or rotation and may be influenced by tethering. There is also a directional bias when using Doppler technology. Myocardial motion may not necessarily be linear. Unless the motion we assess is correctly lined up with the Doppler signal, velocity measurements will be under-estimated. Furthermore, the myocardial segment of interest may move outside the sampling area, or another area of myocardium may move into the sampling area. This is particularly true when sampling for annular velocities as the annulus clearly moves outside of the sampling area during the cardiac cycle. When assessing annular motion, calcification may alter velocity. In contrast to transthoracic echocardiography, with transesophageal echocardiography, the ventricles are distal to valves which, when calcified or prosthetic, shadow the desired sampling sites. All these factors may prevent accurate measurements or produce errors in velocities. The motion of the heart is fixed at the apex, therefore basal or annular velocities represent the sum of activity below them in both systole and diastole and are readily assessed using spectral pulsed wave TD (PWTD). This greatly simplifies the assessment, yet remains a merely regional assessment since only one area can be assessed at a time and not all areas of the heart line up with the Doppler plane. Under normal conditions or evenly distributed disease processes, this may well be extrapolated to global function. However, it may be significantly erroneous in the presence of regional abnormalities. Furthermore, myocardial velocities are inhomogeneous throughout the heart and may vary with age.2 This added level of complexity may make proper assessments challenging in the OR. Myocardial motion can be qualitatively assessed using TD color-coded pixels overlaid on the 2D image. To simplify the assessment, anatomical color M mode has been used to assess motion or deformation by tracing a line along the heart wall and observing streaks of color change over time (Fig. 1). The manufactured image is very pretty and worthy of framing; however, the information is merely qualitative and obscures the limitations of the Doppler angle. It is a step backward in the assessment of heart function by reducing imaging to one dimension over time.Figure 1.: Anatomical color M mode applied to the lateral wall of the right ventricle (left panel) and displayed in color on right. Color is coded for strain with the darkest red being the largest negative strain (shortening). On the right panel, the y axis displays color from the starting point (top, annulus) to the ending point (bottom, apex) in cm. The x axis is time.Powerful and expensive software has been developed to process and manipulate coded color pixels which can then be sampled and graphically represented. The measured velocities, however, cannot be compared to spectral PWTD as they are “averaged” velocities within the sample volume. This has led to some confusion and has added another layer of complexity when comparing these measurements to standard values determined using PWTD. However, there is vastly improved spatial resolution using this technique at the expense of temporal resolution. Color TD is computer-intensive and the larger the 2D image, the lower the frame rate. The anticipation of assessing short-lived isovolumic events is thwarted by the poor frame rate and noise. Furthermore, off-line assessments are time-consuming and impractical in the OR. It has nevertheless satisfied our need to put quick numbers on our assessments and has therefore continued to march forward. The information available from sampling velocities from color pixels has mushroomed: tissue tracking and synchronization, strain rate and strain to name a few. To overcome translation and rotational influences, deformation assessments have been derived using velocity differences.3 This is where it gets substantially more complicated. The measurements of strain are not the result of direct length measurements. To obtain this deformation information, we must derive it indirectly from velocity differences separated by a known distance (offset). The sample volume is fixed and there is no established standard sample size or offset distance. Furthermore, these values are infrequently reported in studies. The shape of the sample volume can be manipulated to fit the myocardium in question; however, the Doppler plane must still be respected. The sample volume can be tracked manually to remain in an area of interest, but the tedium involved is insurmountable in any clinical setting. When displayed graphically, strain rate calculation frequently suffers from excessive noise, rendering it frequently unreadable (Fig. 2). Smoothing algorithms must be applied reducing spatial and/or temporal resolution. Strain rate integration is performed to obtain deformation.4 Although this Eulerian (natural) strain can be related mathematically to Lagrangian strain (direct length measurements), there remain some problems with the technique. First, there is the problem of drift, a complex mathematical by-product of integration, which must be accounted for3,5 (Fig. 3). Second, only areas where motion lies reasonably along the Doppler plane should be assessed. The heart is a three dimensional structure with deformation along all three axes, some shortening, others lengthening during systole. Inappropriate Doppler plane interrogation may result in hybrid measurements of shortening and lengthening, resulting in errors.5 Third, as the sample volume and offset distance are fixed, velocity sampling may drift into nonmobile tissue during the cardiac cycle resulting in erroneous measurements. Alternatively, stationary reverberation may also be recorded as zero velocities thereby altering strain values. Finally, there is human nature; the sample volume is moved along the area of interest until a satisfactory trace is obtained, leading to some degree of bias. The “measurements” of strain and strain rate are gaining momentum in the assessment of heart function. These are highly manufactured numbers and most clinicians have a limited understanding of how they are acquired. In color TD processed for strain, for example, strain may be observed in structures outside the heart (Fig. 4). Understanding why is crucial to the proper use of this technology.Figure 2.: Representative quantitative display from analysis of strain rate over one cardiac cycle at two locations separated by approximately 1 cm within the myocardium. Excessive noise can make assessments challenging.Figure 3.: Strain analysis without drift compensation. (A) longitudinal inferior wall right ventricular strain, (B) left ventricular inferior wall radial strain. Compensation can be linear or reset to zero for each cycle.Figure 4.: Transgastric short axis view of the left ventricle with tissue Doppler color-coded for strain applied to a sector overlying the inferior and anterior walls. Strain can be detected in extra-cardiac tissue (arrows).What do tissue velocities and their derivatives represent? The ability of the heart to pump blood depends on its capacity to perform external work. The problem lies in how we measure work or its components and how we understand them. For example, everyone understands automotive performance as it relates to torque and horsepower, or so they think! Which is more important to know? What does each tell you about the engine? How is the engine assessed? A large amount of torque, say, 300 ft-lbs at 4000 rpm, is desirable as it is the factor responsible for the push back into your seat during acceleration. Calculated power would then be approximately 228 hp (300 × 4000/5252). What about the work generated by a large wheel, say, a wind mill? This huge wheel can generate enormous amounts of torque but, revolving at only 10 rpm, it will only develop a fraction of the horsepower a car will. Ergo, power is the rate of work. We normally observe changes in chamber dimensions such as ejection fraction or fractional area of change, which are the end result of forces within and acting upon the heart, such as contractility and load. Apart from load, we are now able to measure, using TD, some of the components of power, such as the velocity of tissue, its acceleration, deformation (strain), and rate of deformation (strain rate). But, our limited sampling is like measuring the output of one cylinder in a car and rating the whole engine according to this. We must still infer load (the number of passengers, the weight of the car, and the grade). TD for the assessment of heart function has become very attractive, but is it ready for the OR? Intraoperative TD using transesophageal echocardiography has been deemed feasible during cardiac surgery but in a limited number of segments in the OR.6 It is very enticing to believe that one simple and quick method can be used to extrapolate global function, detect ischemia and predict outcome or viability. Is this clinically useful or required in the OR setting? Interpretations are often difficult and complex; witness the myriad conditions which must be applied just to determine diastolic function from annular and flow velocities.7 Furthermore, it does not provide us with information on how volume is handled by the heart. Unfortunately, it is still looking for its proper place in the pantheon of tools to assess performance and pathology in the OR, and there has been no generalized epiphany to date. For the moment, it remains problematic and limited due to its heavy reliance on Doppler planes, limited sites of assessment and different normal values, depending on site and age. More significantly, poorly understood limitations and lack of appreciation for how the information is gathered for the more elaborate components of the technology can lead to erroneous conclusions. Newer methods have been developed to overcome the limitations of TD myocardial imaging. B mode ultrasound imaging creates characteristic features, such as speckling patterns. These natural acoustic markers are stable and move along with tissue. Speckle tracking (feature or pixel tracking) is a technology which uses search algorithms in an attempt to track myocardial speckling patterns frame by frame.8,9 The filtering out of random speckles enhances accuracy. Spatial and temporal smoothing can be applied to the velocity vectors within a desired region. Information derived from Speckle tracking allows for the quantification of myocardial function according to tissue velocity, deformation, deformation rate, displacement and rotation, to name a few. This methodology is computer-intensive and is relatively “black box” in its application. In other words, the computer performs a large amount of automatic work in the background while we wait for results. Its application is relatively simple; in a standard view, the desired endocardium is traced during peak systole along which an area of myocardium is included (and selected). This is then separated into several areas of interest for analysis. The computer analyzes the speckles, their motion, and the tracking quality. A tracking score or a pass/fail is provided for each segment of myocardium. Once accepted, derived parameters can be represented qualitatively or quantitatively. For example, color-coded pixels can be overlaid on the 2D image for a qualitative assessment of strain in real time. (Videos 1 and 2 [loops], please see video loop available at www.anesthesia-analgesia.org). At first glance, this application seems very attractive as it is angle-independent and can simultaneously assess two dimensions, i.e., radial, longitudinal or circumferential, depending on the view. It is, however, dependent on the quality of the 2D image. Unfortunately, it can also be limited by temporal resolution. Low frame rates result in tracking failure due to inability to follow the features frame by frame, (i.e., they move too far away between frames and are “lost”). Increasing frame rate without reducing image size, results in a loss of 2D (lateral) resolution and inability to track correctly. Furthermore, tissue attenuation, such as when assessing the lateral walls in four chamber or transgastric short axis views, will result in poor tracking. It is thus essential to visually inspect tracking quality before accepting measurements. Quantitative assessments are possible using speckle tracking.10 Information is processed according to velocity measurements just as with TD, however, the heart can be analyzed in its entirety (for the view) and in two dimensions. Quantitative assessment for the image in Video 1 is demonstrated in Figure 5. The average of each color-coded segment is plotted over the cardiac cycle for longitudinal strain rate on the left and longitudinal strain on the right. In the familiar transgastric short axis view, rotation can also be assessed11 (Fig. 6). Twisting and untwisting may open new avenues for systolic and diastolic assessments.12Figure 5.: (A) longitudinal strain rate of left ventricle in mid-esophageal 2 chamber view and (B) longitudinal strain in mid-esophageal 2 chamber view using speckle tracking. Each color-coded segment is represented graphically over one cardiac cycle. The white dotted line represents the global value.Figure 6.: Rotation rate (A) and rotation (B) of the left ventricle (LV) in transgastric short axis view (inset) near apex calculated using speckle tracking. Each segment of the LV is represented in different colors. The white dotted line represents the global value.In summary, two newer technologies are at our disposal for the assessment of velocity-based ventricular systolic and diastolic function. TD has disadvantages, such as Doppler angle limitation, limited sites of interrogation and one-dimensional assessments per view. Some aspects remain attractive; however, its use may remain limited in scope in the OR. Speckle tracking offers the advantage of simultaneous whole image assessment in two dimensions, but requires a very good 2D image. It is likely that some aspects of each technology will find their place in our OR echo armamentarium; however, they will likely be complementary to current techniques. It is essential that we understand the principles and limitations of these new technologies and rigorously evaluate them in order to determine clinical usefulness in the OR.
No takes yet. Share an insight, caveat, or question.
Claude Tousignant (2008) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: