Why the study?
To develop an MR multitasking-based multidimensional assessment of the cardiovascular system (MT-MACS) with electrocardiography-free and navigator-free acquisition for evaluating thoracic aortic diseases.
Does MT-MACS provide comparable quantitative measurements to conventional 2D sequences for assessing the thoracic aorta?
Does MT-MACS provide comparable quantitative measurements to conventional 2D sequences for assessing the thoracic aorta?
MT-MACS is a feasible, ECG- and navigator-free technique that provides high-quality, multidimensional images of the thoracic aorta with good agreement to conventional 2D sequences.
Answers are grounded in this paper and cite their sources.
May enable ECG- and navigator-free aortic assessment; leaves open clinical utility pending validation.
PURPOSE: To develop an MR multitasking-based multidimensional assessment of cardiovascular system (MT-MACS) with electrocardiography-free and navigator-free data acquisition for a comprehensive evaluation of thoracic aortic diseases. Twelve healthy subjects and 2 patients with thoracic aortic diseases were recruited for the study at 3 T, and both qualitative (image quality score) and quantitative (contrast-to-noise ratio between lumen and wall, lumen and wall area, and aortic strain index) analyses were performed in all healthy subjects. The overall image quality was scored based on a 4-point scale: 3, excellent; 2, good; 1, fair; and 0, poor. Statistical analysis was used to test the measurement agreement between MT-MACS and its corresponding 2D references. RESULTS: The MT-MACS images reconstructed from acquisitions as short as 6 minutes demonstrated good or excellent image quality for bright-blood (2.58 ± 0.46), dark-blood (2.58 ± 0.50), and gray-blood (2.17 ± 0.53) contrast weightings, respectively. The contrast-to-noise ratios for the three weightings were 49.2 ± 12.8, 20.0 ± 5.8 and 2.8 ± 1.8, respectively. There were good agreements in the lumen and wall area (intraclass correlation coefficient = 0.993, P < .001 for lumen; intraclass correlation coefficient = 0.969, P < .001 for wall area) and strain (intraclass correlation coefficient = 0.947, P < .001) between MT-MACS and conventional 2D sequences. CONCLUSION: The MT-MACS technique provides high-quality, multidimensional images for a comprehensive assessment of the thoracic aorta. Technical feasibility was demonstrated in healthy subjects and patients with thoracic aortic diseases. Further clinical validation is warranted.
No takes yet. Share an insight, caveat, or question.
Hu et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: