Key result
Both double-sensor and single-sensor cardiorespiratory gating strategies provided images with improved spatial resolution, fewer artifacts, and 100% correct TTL signals in mice.
Both single- and double-sensor digital cardiorespiratory gating strategies are efficient for high-resolution dynamic contrast-enhanced MRI of atherosclerosis in mice.
Enables high-resolution murine atherosclerosis MRI; extends preclinical gating options but leaves clinical translation open.
Atherosclerosis initially develops predominantly at the aortic root and carotid origin, where effective visualization in mice requires efficient cardiac and respiratory gating. The present study sought to first compare the high-resolution MRI gating performance of two digital gating strategies using: 1) separate cardiac and respiratory signals (double-sensor); and 2) a single-sensor cardiorespiratory signal (ECG demodulation), and second, to apply an optimized processing technique to dynamic contrast-enhanced (CE) carotid origin vessel-wall imaging in mice. High-resolution MR mouse heart and aortic arch images were acquired by ECG signal detection, digital signal processing, and gating signal generation modeled using Simulink (MathWorks, USA). Double-sensor gating used a respiratory sensor while single-sensor gating used breathing-modulated ECG to generate a demodulated respiratory signal. Pre- and postcontrast T(1)-weighted images were acquired to evaluate vessel-wall enhancement with a gadolinium blood-pool agent (P792; Guerbet, France) at the carotid origin in vivo in ApoE(-/-) and C57BL/6 mice, using the optimized cardiorespiratory gating processing technique. Both strategies provided images with improved spatial resolution, less artifacts, and 100% correct transistor-to-transistor logic (TTL) signals. Image quality allowed vessel-wall enhancement measurement in all the ApoE(-/-) mice, with maximal (32%) enhancement 27 min postinjection. The study demonstrated the efficiency of both cardiorespiratory gating strategies for dynamic contrast-enhanced vessel-wall imaging.
No takes yet. Share an insight, caveat, or question.
Alsaid et al. (2007) studied Atherosclerosis. Double-sensor gating and single-sensor gating (ECG demodulation) was evaluated on Image quality and vessel-wall enhancement. Both double-sensor and single-sensor cardiorespiratory gating strategies provided images with improved spatial resolution, fewer artifacts, and 100% correct TTL signals in mice.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: