Why the study?
Perioperative and median-term outcomes had not been compared between radiofrequency ablation devices for permanent AF concomitant with rheumatic valve disease.
Does non-irrigation radiofrequency ablation compared to irrigation radiofrequency ablation improve sinus rhythm restoration in patients with permanent atrial fibrillation undergoing rheumatic valve surgery?
Does non-irrigation radiofrequency ablation compared to irrigation radiofrequency ablation improve sinus rhythm restoration in patients with permanent atrial fibrillation undergoing rheumatic valve surgery?
Both non-irrigation and irrigation bipolar radiofrequency ablation devices are similarly effective and safe for restoring sinus rhythm during concomitant rheumatic valve surgery.
Answers are grounded in this paper and cite their sources.
Similar sinus rhythm rates support interchangeable non-irrigation and irrigation ablation; hypothesis-generating, needs RCTs before practice change.
BACKGROUND: Perioperative and median-term follow-up outcomes have not been compared among procedures using radiofrequency ablation devices for permanent atrial fibrillation with concomitant rheumatic valve disease. We compared the sinus rhythm restoration efficacy of "non-irrigation" ablation forceps and an "irrigation" ablation device in patients with rheumatic valve disease undergoing a modified Cox maze radiofrequency ablation procedure due to permanent atrial fibrillation. METHODS: Data of 278 patients with rheumatic valve disease from the Cardiac Surgery Department of Sichuan Provincial People's Hospital who underwent the modified Cox maze radiofrequency ablation procedure between May 2013 and May 2017 were reviewed. The procedure was performed using "non-irrigation" ablation forceps (AtriCure, group A) in 149 patients and an "irrigation" ablation device (Medtronic, group M) in 129 patients. Data were collected prospectively, and follow-up was documented and compared between the groups. RESULTS: The radiofrequency procedure duration was 28.9 ± 3.8 min in group A and 29.5 ± 2.8 min in group M (t = 1.623, P = 0.106). The predicted radiofrequency time to the left atrium diameter was (Ya = 0.4964 X + 0.3762, R = 0.74) in group A and (Ym = 0.4331 X + 4.3563, R = 0.8435) in group M. The sinus rhythm (SR) conversion rate without use of anti-arrhythmic drugs was similarly good in groups A and M, with 75.2%, 72.5%, and 70.5% vs. 73.6%, 71.3%, and 69.8% at discharge, 6 and 12 months, respectively (F = 0.084, F = 0.046, F = 0.046, P > 0.05, respectively). CONCLUSION: Two types of radiofrequency ablation devices characteristic of "non-irrigation" and "irrigation" bipolar ablation forceps were similarly efficient at SR restoration.