The amplitude of sarcoplasmic reticulum Ca2+ release in frog skeletal muscle is graded by the frequency, rather than the amplitude or spatio-temporal extent, of individual Ca2+ sparks.
Answers are grounded in this paper and cite their sources.
Frequency grades SR Ca2+ release amplitude in frog muscle; extends spark models but leaves open mammalian cardiac translation.
Brief localized elevations in myoplasmic [Ca2+] (Ca2+ sparks) in individual sarcomeres of voltage-clamped frog skeletal muscle fibres were examined by laser scanning confocal microscopy. 2. Fibres held at 0 mV were briefly repolarized to -90 mV (repriming pulse) to restore only a small fraction of sarcoplasmic reticulum (SR) calcium release. Subsequent depolarization to 0 mV (test pulse) caused the appearance of small numbers of Ca2+ sparks at different sarcomeres from pulse to pulse. Increasing the repriming time resulted in an increase in the frequency of occurrence of the Ca2+ sparks. 3. The amplitude and spatio-temporal extent of the Ca2+ sparks were independent of the repriming time and test pulse voltage. Ca2+ sparks recorded during small depolarizations of fibres held at -90 mV had a similar amplitude and spatio-temporal extent as those recorded after brief repriming of the same fibre held at 0 mV. 4. We conclude that stereotyped Ca2+ sparks underlie calcium release at all voltages and all extents of repriming. The amplitude of Ca2+ release is thus graded by the frequency but not by the amplitude or spatio-temporal extent of the individual SR Ca2+ release events.
No takes yet. Share an insight, caveat, or question.
Lacampagne et al. (1996) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: