Key result
Transcatheter closure of multiple secundum atrial septal defects using multiple occluder devices achieved 100% procedural success with no major late complications over a median 5.5-year follow-up.
Why the study?
Multiple devices are needed to close large multiple atrial septal defects separated by more than 6 mm, but there is concern regarding complications, particularly in children.
Does transcatheter closure using multiple occluder devices provide safe and effective treatment in patients with multiple secundum atrial septal defects?
Observational (n=25)
No
Does transcatheter closure using multiple occluder devices provide safe and effective treatment in patients with multiple secundum atrial septal defects?
Transcatheter closure of multiple atrial septal defects using multiple devices is feasible and safe, with no major late complications over long-term follow-up.
Answers are grounded in this paper and cite their sources.
May support multi-device closure of selected distant multiple ASDs at expert centers; leaves open larger prospective confirmation.
Background: Device closure of multiple atrial septal defects (MASDs) is frequently done using a single centrally deployed septal or cribriform occluder, but multiple devices are needed for large defects separated more than 6 mm. There is a concern about complications while using multiple devices, especially in children. Methods: Patients who received multiple devices for closure of MASD were grouped according to their age and analyzed for procedural techniques, immediate and late complications. MASDs closed by a single device were not included. Balloon sizing was done when echocardiographic images were suboptimal before simultaneous device deployment through two venous accesses or sequential deployment through one access. Duration and number of antiplatelet drugs and residual flows were analyzed on follow-up. Results: Twenty-five patients received multiple devices. Balloon interrogation was performed in 16/18 adults but only in 2/7 children. Device size was 2-5 mm larger than echocardiographic defect size or equal to balloon waist. There were no procedural failures; 7/25 showed small postprocedural residual flows. Complications including embolization in one, arrhythmia in one, and cobra deformity in two were managed successfully. On a median follow-up of 5.5 years (1-12 years), residual flows disappeared in 4/7 and there were no major late complications. Conclusions: Use of multiple devices for closing MASD is feasible with good technical success. Echocardiography and balloon interrogation are the keys for success. Simultaneous deployment is often needed and sequential delivery is feasible rarely if the defects are far apart. Minor residual leaks are common but improve on follow-up. There are no significant new complications on long-term follow-up.
No takes yet. Share an insight, caveat, or question.
Sagar et al. (2022) conducted an observational in Multiple secundum atrial septal defects (n=25). Transcatheter closure using multiple occluder devices was evaluated on Procedural success and complications. Transcatheter closure of multiple secundum atrial septal defects using multiple occluder devices achieved 100% procedural success with no major late complications over a median 5.5-year follow-up.
Synapse has enriched 10 related papers. Consider them for comparative context: