Key result
Atrial septum remodeling enables immediate complete closure in ~82% of multiple ASD cases.
Why the study?
Multiple nearby atrial septal defects not eligible for transcatheter closure require alternative closure methods, and feasibility of a new atrial septum remodeling technique was investigated.
Does an atrial septum remodeling technique facilitate successful intra-operative device closure of multiple ASDs in adult patients?
Does an atrial septum remodeling technique facilitate successful intra-operative device closure of multiple ASDs in adult patients?
Answers are grounded in this paper and cite their sources.
An atrial septum remodeling technique safely and effectively facilitates intra-operative single-device closure of multiple ASDs that are otherwise ineligible for transcatheter closure.
OBJECTIVE: We introduced a new atrial septum remodeling technique and further investigated the feasibility of this method in facilitating the intra-operative device closure (IODC) of multiple atrial septal defects (ASDs). METHODS: Adult patients with multiple nearby ASDs, which were not eligible for transcatheter closure, were enrolled in this study. Transesophageal echocardiogram (TEE) was applied for intra-operative evaluation. The multiple ASDs were divided into three different types according to its morphology. Based on the concept of breaking the rim between multiple ASDs and making it feasible for single device closure, atrial septum remodeling procedure was carried out via pre-atrial approach using special clamp under the guidance of TEE. IODC was then attempted for reshaped ASD. Successful rate and perioperative complications were then noted. RESULTS: Eleven patients were enrolled in this study, with mean age being 23.4 ± 5.3 years and mean weight 51.6 ± 8.0 kg. Among them, seven patients have double ASDs and four have triple ASDs. Mean diameter of isolated ASD was 10.4 ± 3.8 mm with a mean distance of 3.2 ± 1.2 mm between each other. Atrial septum remodeling procedure was successfully done in all patients. One device was then used for each patient. Mean ASD diameter after remodeling procedure was 20.6 ± 3.9 mm with mean device size 23.5 ± 4.0 mm. Complete closure of multiple ASDs was achieved in nine patients immediately after the procedure; two patients had trivial grade shunt after device deployment that resolved within the 3-month follow-up. No severe complications were noticed during the perioperative period and the 3-month follow-up. CONCLUSIONS: Atrial septum remodeling technique seems to be a safe and effective method that could largely facilitate the successful IODC of multiple ASDs.
No takes yet. Share an insight, caveat, or question.
Zhu et al. (2011) studied Multiple atrial septal defects (ASDs) (n=11). Atrial septum remodeling technique facilitating intra-operative device closure (IODC) was evaluated on Complete closure of multiple ASDs immediately after the procedure. An atrial septum remodeling technique facilitated successful intra-operative device closure of multiple ASDs, achieving immediate complete closure in 81.8% of patients with no severe complications.
Synapse has enriched 10 related papers. Consider them for comparative context: