The design of cone calorimeters for laser energy measurements must take account of fabrication difficulties. The surface treatment is particularly important. Using an electroplating technique, cones of good geometry combining the absorptivity of nickel and the thermal diffusivity of copper are easily manufactured. It is shown that total energies cannot be inferred from measured average temperatures, but an alternative method is suggested which relies on the maximum recorded tip temperature. The more complex re-entrant design does not offer this advantage.
No takes yet. Share an insight, caveat, or question.
Barbara Scott (1966) studied this question.