Key result
A novel sandwich ELISA for human angiotensinogen demonstrated high linearity and low intra- and interassay coefficients of variation with negligible cross-reactivity.
A newly developed sandwich ELISA provides a sensitive and specific method to measure human angiotensinogen, enabling future studies on its utility as a biomarker for RAS blockade responsiveness in hypertension.
Answers are grounded in this paper and cite their sources.
Novel ELISA enables precise human angiotensinogen measurement; leaves open its clinical utility as RAS blockade biomarker pending validation.
We recently reported that urinary excretion rates of angiotensinogen (U(AGT)) provide a specific index of intrarenal renin-angiotensin (ANG) system (RAS) status in ANG II-dependent hypertensive rats. When this is shown to be applicable to human subjects, a diagnostic test to identify those hypertensive patients most likely to respond to an RAS blockade could provide useful information to allow a mechanistic rationale for selection of an optimized approach to treatment of hypertensive patients. However, simple and accurate methods to measure human angiotensinogen (hAGT) are unavailable. For future studies of human subjects, we developed antibodies and a sensitive and specific quantification system for hAGT using a sandwich ELISA. We raised two antibodies against hAGT: a mouse monoclonal antibody and a rabbit polyclonal antibody. The standard curve of this ELISA exhibited a high linearity (0.31-20 ng/ml). The correlation coefficient was >0.99. Plasma angiotensinogen concentrations of healthy volunteers ranged from 28 to 71 microg/ml (n = 10). The ratio of U(AGT) to urinary creatinine concentration ranged from 5.0 to 30 microg/g (n = 7). Intra- and interassay coefficients of variation ranged from 4.4 to 5.5% and from 4.3 to 7.0%, respectively. This ELISA system had no cross-reactivity with major proteins in proteinuric urine samples, such as human albumin, immunoglobulin, or transferrin. Moreover, the cross-reactivity of the system with angiotensin peptides was also negligible. This hAGT ELISA will be a useful tool to investigate the relationship of U(AGT) and reactivity to antihypertensive drugs in hypertensive patients.
No takes yet. Share an insight, caveat, or question.
Katsurada et al. (2007) studied Healthy volunteers (n=17). Sandwich ELISA for human angiotensinogen was evaluated on Assay linearity, correlation coefficient, and coefficients of variation. A novel sandwich ELISA for human angiotensinogen demonstrated high linearity and low intra- and interassay coefficients of variation with negligible cross-reactivity.
Synapse has enriched 10 related papers. Consider them for comparative context: