Key result
There was no detectable clearance or hydrolysis of big-endothelin-1 in the pulmonary circulation, whereas the heart extracted 14 +/- 1% of the injected tracer.
Circulating big-endothelin-1 is not hydrolyzed by luminal endothelin-converting enzymes in the pulmonary or coronary circulations, though mild coronary uptake occurs.
The endothelin-converting enzymes are distributed on both the surface of the endothelium and intracellularly. Whether circulating big-endothelin-1 can be hydrolyzed in plasma by lumen-bound endothelin-converting enzymes is unknown. The lung is the major site for hydrolysis of angiotensin-I to angiotensin-II by the angiotensin-converting enzyme; because of its high content in endothelin-converting enzymes, we hypothesized that the lung could similarly hydrolyze circulating big-endothelin-1. Since big-endothelin-1 produced by the lung can modulate coronary vascular tone, the heart may also have the capacity to hydrolyze circulating big-endothelin-1. Isolated lungs and hearts from Sprague-Dawley rats were perfused at 10 mL/min. Clearance of trace doses of human I125big-endothelin-1 was quantified using the indicator-dilution curves technique with labeled albumin as a vascular reference. Single-pass hydrolysis was assessed by bolus injection of human big-endothelin-1 (24 fmol) followed by serial ELISA determinations of big-endothelin-1 and endothelin-1 levels in effluent samples. To exclude possible uptake of produced endothelin-1, 10(-6) M BQ788 was added to the perfusate. The injections had no effect on perfusion pressures. There was no detectable clearance of I125big-endothelin-1 in the lung; however the heart extracted 14 +/- 1% of the injected tracer. There was no detectable big-endothelin-1 hydrolysis in the pulmonary as well as in the coronary circulations. The pulmonary circulation does not clear or hydrolyze circulating big-endothelin-1 suggesting that endothelin-converting enzymes are predominantly used for intracellular and/or abluminal conversion of locally produced big-endothelin-1. Mild coronary uptake of big-endothelin-1 suggests that this circulating peptide could modulate coronary vascular tone.
No takes yet. Share an insight, caveat, or question.
Jasmin et al. (2003) studied this question. Bolus injection of human big-endothelin-1 was evaluated on Clearance and hydrolysis of big-endothelin-1. There was no detectable clearance or hydrolysis of big-endothelin-1 in the pulmonary circulation, whereas the heart extracted 14 +/- 1% of the injected tracer.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: