Key result
Omitting defibrillation testing at S-ICD implantation shows no increase in death or ineffective shocks.
Why the study?
Defibrillation efficacy testing (DT) is recommended at subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation, but adherence is declining in clinical practice, motivating a comparison of clinical outcomes between patients who underwent DT and those with omitted DT.
Case-Control (n=1,652)
Yes
None. Background: Defibrillation efficacy testing (DT) is recommended at implantation of subcutaneous implantable cardioverter–defibrillators (S- ICD). However, prior works found that adherence to this recommendation is declining in clinical practice. Purpose: To compare survival from all-cause death and first ineffective shock (primary endpoint) and the composite of all-cause death, inef- fective shock, inappropriate shock and device-related complication (secondary endpoint) between patients who underwent DT and those with omitted DT. Methods: We analyzed 1652 consecutive patients who underwent S-ICD implantation in 60 Italian centers from 2013 to 2019. Results: DT was not performed in 325 (20%) patients (no-DT patients). As compared with the DT group, these patients were older (51 ± 16 vs. 48 ± 15 years; p < 0.01) and had lower ejection fraction (37 ± 16% vs. 46 ± 16%; p < 0.01). The 325 no-DT patients were propensity matched with 325 patients of the DT group. During a median follow up of 19 months, 27 (4.2%) patients died for any-cause. During follow- up, 34 (5.2%) patients received appropriate shocks to treat discrete episodes of VT/VF. The first shock was effective in 30 out of 34 patients (88%), whereas a second shock was required to terminate VT/VF in 3 patients and a third shock in the last one. The primary endpoint occur- red in 31 (4.8%) patients, and the risk was not significantly increased in the no-DT cohort (HR = 1.26, 95%CI:0.62-2.55, p = 0.522). Inappropriate shocks were reported in 36 (5.5%) patients and device-related complications in 25 (3.8%) patients during follow-up. Survival from the composite secondary endpoint was comparable between groups (HR = 0.86, 95%CI:0.57-1.32, p = 0.500). Conclusions: Our data confirmed that DT is frequently omitted in current clinical practice, especially in older patients with worse systolic function. A strategy that omits DT did not appear to compromise the effectiveness of the S-ICD and no additional risk seems associated with DT omission at a mid-term follow-up. These data suggest that routine DT at S-ICD implant might not be necessary. Randomized trials are needed to confirm this finding.
No takes yet. Share an insight, caveat, or question.
Bianchi et al. (2021) conducted a case-control in Patients undergoing subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation (n=1,652). Omission of defibrillation efficacy testing (no-DT) at S-ICD implantation vs. Defibrillation efficacy testing (DT) performed at S-ICD implantation was evaluated on Composite of all-cause death and first ineffective shock (HR 1.26, 95% CI 0.62-2.55, p=0.522). Omitting defibrillation testing at S-ICD implantation did not significantly increase the risk of all-cause death or first ineffective shock compared with performing testing (HR 1.26; 95% CI 0.62-2.55).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: