Key result
In fetal sheep, beat-by-beat pulmonary artery forward and backward compression wave relationships were highly linear during extrasystoles, indicating the backward wave regulates pulmonary hemodynamics.
In a fetal sheep model, the pulmonary artery backward-running compression wave contributes to beat-to-beat regulation of both pulmonary artery and pulmonary trunk hemodynamics.
Answers are grounded in this paper and cite their sources.
No immediate clinical implications; extends pulmonary wave dynamics to fetal sheep but leaves human translation open.
Steady-state wave intensity (WI) analysis indicates that characteristic midsystolic falls in fetal pulmonary trunk (PT) and artery (PA) blood flow are due to an extremely large backward-running compression wave (BCW(ms)) that 1) originates from the pulmonary microvasculature by a combination of cyclical pulmonary vasoconstriction and vascular reflection of the forward-running compression wave (FCW(is)) associated with impulsive right ventricular ejection, and 2) is transmitted into the PT. However, no information is available about the dynamic properties of PA BCW(ms) and its contribution to beat-to-beat regulation of pulmonary hemodynamics. Accordingly, beat-by-beat WI analysis was performed during brief increases in ventricular contractility accompanying an extrasystole (ES) in nine anesthetized late-gestation fetal sheep instrumented with PT and left PA micromanometer catheters to measure pressure (P) and transit-time flow probes to obtain blood velocity (U). WI was calculated as the product of P and U rates of change. At steady state, the magnitude of PA BCW(ms), and its associated P and U changes (DeltaP and DeltaU, respectively), were similar to those of FCW(is). The PA FCW(is) and BCW(ms), and their accompanying DeltaP and DeltaU, were all transiently potentiated after an ES. Beat-by-beat PA FCW(is)-BCW(ms) wave area, DeltaP and DeltaU relationships were highly linear (R(2) > or = 0.91) with slopes of 1.36-1.47 (P < 0.001), consistent with the presence of a vasoconstrictor component in PA BCW(ms). PA-PT BCW(ms) area and DeltaP and DeltaU relationships were also linear (R(2) > or = 0.77) with slopes of 0.23-0.64 (P < 0.001). These results indicate that the fetal PA BCW(ms) contributes to beat-to-beat regulation of not only PA but also PT hemodynamics.
No takes yet. Share an insight, caveat, or question.
Smolich et al. (2009) studied Fetal pulmonary hemodynamics (n=9). Cardiac extrasystoles vs. Steady state was evaluated on Beat-by-beat pulmonary artery forward and backward compression wave relationships (p=<0.001). In fetal sheep, beat-by-beat pulmonary artery forward and backward compression wave relationships were highly linear during extrasystoles, indicating the backward wave regulates pulmonary hemodynamics.
Synapse has enriched 10 related papers. Consider them for comparative context: