Why the study?
In certain clinical situations, it is necessary to determine whether clinically relevant plasma levels of DOACs are present, prompting investigation into whether urine DOAC dipstick testing can exclude plasma concentrations ≥30 ng/mL.
Does DOAC Dipstick testing in urine reliably exclude clinically relevant DOAC plasma concentrations (≥30 ng/mL) in patients treated with DOACs?
Does DOAC Dipstick testing in urine reliably exclude clinically relevant DOAC plasma concentrations (≥30 ng/mL) in patients treated with DOACs?
DOAC Dipstick testing in urine can reliably exclude clinically relevant DOAC plasma concentrations (≥30 ng/mL) with 100% negative predictive value.
Answers are grounded in this paper and cite their sources.
May support point-of-care exclusion of relevant DOAC levels; leaves open prospective validation before routine use.
In certain clinical situations, it is necessary to determine whether clinically relevant plasma levels of direct oral anticoagulants (DOACs) are present. We examined whether qualitative testing of DOACs in urine samples can exclude DOAC plasma concentrations of ≥30 ng/mL. This prospective single-center cohort study included consecutive patients treated with an oral direct factor Xa inhibitor (DXI) (apixaban, n = 31, rivaroxaban, n = 53) and direct thrombin inhibitor (DTI) (dabigatran, n = 44). We aimed to define the negative predictive value (NPV) and other statistical parameters of detecting DXIs and DTIs by DOAC Dipstick at plasma concentrations of ≥30 ng/mL. We also determined the best-fit threshold plasma levels using chromogenic substrate assays by logistic regression analysis. Between July 2020 and July 2021, 128 eligible patients (mean age 66 years, 55 females) were included into the study. The NPVs and sensitivities for DXI and DTI of DOAC Dipstick were 100% at ≥30 ng/mL plasma, for specificities 6 and 21% and for positive predictive values 62 and 72%, respectively. All diagnostic statistical tests improved to values between 86 and 100% at best-fitting plasma thresholds of ≥14 ng/mL for DXI and ≥19 ng/mL for DTI. Visual analysis using the DOAC Dipstick was 100% in agreement with that of the optoelectronic DOASENSE Reader for all the three DOACs. DOAC Dipstick testing can reliably exclude the presence of DOACs in urine samples at best-fitting thresholds of >14 and >19 ng/mL in plasma. The performance of the DOAC Dipstick at detecting lower DOAC concentrations in plasma requires confirmation.
No takes yet. Share an insight, caveat, or question.
Margetić et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: