Why the study?
Measuring direct oral anticoagulant concentrations may be necessary in certain clinical situations but is not routinely performed.
Does the DOAC Dipstick test accurately detect direct oral anticoagulants in urine compared to a clinically relevant plasma threshold concentration in patients taking DOACs?
Does the DOAC Dipstick test accurately detect direct oral anticoagulants in urine compared to a clinically relevant plasma threshold concentration in patients taking DOACs?
The DOAC Dipstick is a reliable rapid test for detecting clinically relevant concentrations (≥30 ng/mL) of DOACs in urine, though positive results should be confirmed with plasma testing.
Supports urine dipstick feasibility for relevant DOAC detection; leaves open prospective validation before clinical adoption.
Measuring direct oral anticoagulant (DOAC) concentrations might be necessary in certain clinical situations but is not routinely performed. The DOAC Dipstick is a new rapid test for detecting DOACs in urine. The aim of this study was to evaluate the possible uses and limitations of the DOAC Dipstick and to compare visual analysis and DOASENSE Reader analysis of DOAC Dipstick pads. Plasma and urine samples were collected from 23 patients taking DOACs. DOAC concentrations in plasma and urine were measured by chromogenic substrate assays and in urine also by the DOAC Dipstick. Plasma concentrations were dichotomized at a threshold of ≥30 ng/mL. Patient samples were compared with samples from control individuals not using anticoagulants (n = 10) and with DOASENSE control urines. The Combur-10 test was used to measure parameters that may affect urine color and hence the interpretation of the DOAC Dipstick result. DOAC Dipstick test results were positive in 21/23 patient urine samples at a plasma DOAC concentration of ≥30 ng/mL and in 2/23 patient urine samples at a plasma DOAC concentration of <30 ng/mL. Inter-observer agreement was above 90% for visual analysis of patient urine samples and was 100% for DOASENSE Reader analysis of patient urines and for analysis of control group urines and DOASENSE control urines. Abnormalities in urine color detected by the Combur-10 test did not affect the DOAC Dipstick results. DOAC Dipstick detects DOACs in urine at a plasma threshold of ≥30 ng/mL. Positive DOAC Dipstick results should be confirmed by measuring DOAC plasma concentration.
No takes yet. Share an insight, caveat, or question.
Örd et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: