Why the study?
Does a novel catheter technique accurately measure pericardial constraint compared to balloon transducers and DeltaLVEDP in open-chest dogs?
Population
Six open-chest dogs
Comparison
Novel technique using a catheter positioned… vs Previously placed balloon transducer in the same…
Design
Preclinical
Authors
Loading...
Validates novel pericardial pressure measurement in canine models; leaves open translation to human diastolic constraint assessment.
Does a novel catheter technique accurately measure pericardial constraint compared to balloon transducers and DeltaLVEDP in open-chest dogs?
A novel catheter technique accurately measures pericardial liquid pressure, demonstrating that it defines the diastolic constraining effect of the pericardium and suggesting previous measurements were artifactually low.
deVries et al. (2001) studied this question.