Why the study?
Does a pressure trigger setting prevent mechanical ventilator autocycling compared to a flow trigger in patients with Total Artificial Hearts?
Does a pressure trigger setting prevent mechanical ventilator autocycling compared to a flow trigger in patients with Total Artificial Hearts?
Using a pressure trigger rather than a flow trigger for mechanical ventilation prevents autocycling in patients post-Total Artificial Heart implantation.
Answers are grounded in this paper and cite their sources.
Pressure trigger may avert autocycling in TAH patients; leaves open need for prospective validation before practice change.
Many patients with end-stage cardiomyopathy are now being implanted with Total Artificial Hearts (TAHs). We have observed individual cases of post-operative mechanical ventilator autocycling with a flow trigger, and subsequent loss of autocycling after switching to a pressure trigger. These observations prompted us to do a retrospective review of all TAH devices placed at our institution between August 2007 and May 2009. We found that in the immediate post-operative period following TAH placement, autocycling was present in 50% (5/10) of cases. There was immediate cessation of autocycling in all patients after being changed from a flow trigger of 2 L/minute to a pressure trigger of 2 cm H2O. The autocycling group was found to have significantly higher CVP values than the non-autocycling group (P = 0.012). Our data suggest that mechanical ventilator autocycling may be resolved or prevented by the use of a pressure trigger rather than a flow trigger setting in patients with TAHs who require mechanical ventilation.
No takes yet. Share an insight, caveat, or question.
Shoham et al. (2010) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: