Why the study?
Does a 10-minute venous occlusion affect PAI activity and fibrinolytic response in patients with confirmed deep vein thrombosis?
Does a 10-minute venous occlusion affect PAI activity and fibrinolytic response in patients with confirmed deep vein thrombosis?
Answers are grounded in this paper and cite their sources.
Residual PAI activity after venous stasis can classify DVT patients into good or bad responders, identifying hypofibrinolysis in 54% of patients due to insufficient t-PA release or increased basal PAI activity.
In eighty-three patients with confirmed deep vein thrombosis, the fibrinolytic system was studied before and after a 10-minute venous occlusion. Blood was collected at least 3 months after the last acute episode, and PAI-1 antigen and activity, as well as tissue-type plasminogen activator (t-PA) antigen, urokinase-type plasminogen activator (u-PA) antigen, and fibrinolytic activity were measured in these samples. During venous stasis, plasminogen activator inhibitor (PAI) activity decreased in almost all patients (81 of 83), from a median value of 8.2 to 2.9 U/mL (P less than .001, Wilcoxon signed-rank test). Because PAI-1 antigen augmented from a median value of 16 to 19.2 ng/mL (P less than .001), the decline in PAI activity was attributed to an increase in t-PA antigen from a median value of 10 to 21.7 ng/mL (P less than .001). Neutralization of PAI activity thus reflects the patient's capacity to overcome basal inhibitory potential through t-PA release. Based on residual PAI activity after 10-minute stasis, patients were classified as good or bad responders (PAI activity below detection limit, ie, less than or equal to 1.0 and greater than 1.0 U/ml, respectively). Good responders had a significantly higher fibrinolytic response after stasis than bad responders (median euglobulin clot lysis time 60 v 180 minutes; dilute whole blood clot lysis time 60 v 120 minutes; fibrinolytic activity on fibrin plates 7.7 v 0 U/mL). Furthermore, good responders, as compared with bad responders, had higher t-PA release (median 16.5 v 11.5 ng/mL), lower basal PAI activity (median 4.8 v 11.2 U/mL), and lower basal PAI-1 (median 11 v 21 ng/mL) and u-PA antigen (median 7.9 v 9.0 ng/mL, P less than .02). Hypofibrinolysis, as defined by the inability of released t-PA to overcome PAI-1 basal inhibitory potential, was observed in 45 of 83 patients (54%) and resulted either from an insufficient release of t-PA or from an increased basal PAI activity.
No takes yet. Share an insight, caveat, or question.
Nguyen et al. (1988) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: