Why the study?
Does mechanical circulatory support (VAD) alter endothelin receptor expression in the left ventricular myocardium of patients with dilated cardiomyopathy?
Does mechanical circulatory support (VAD) alter endothelin receptor expression in the left ventricular myocardium of patients with dilated cardiomyopathy?
Mechanical unloading with a ventricular assist device does not significantly alter myocardial endothelin receptor density in patients with dilated cardiomyopathy.
Answers are grounded in this paper and cite their sources.
VAD unloading leaves endothelin receptor density unchanged in DCM; leaves open the clinical relevance of increased ETB mRNA.
BACKGROUND: In terminal failing hearts ventricular assist devices (VAD) are implanted as a bridge to transplantation. Endothelin receptor (ETR) antagonists are used for treatment of secondary pulmonary hypertension in VAD patients. However, the cardiac ETR regulation in human heart failure and during VAD support is incompletely understood. METHODS: In paired left ventricular samples of 12 dilated cardiomyopathy patients we investigated the density of endothelin A (ETA) and B (ETB) receptors before VAD implantation and after device removal. Left ventricular samples of 12 non-failing donor hearts served as control. Receptor quantification was performed by binding of [125I]-ET-1 in the presence of nonselective and ETA selective ETR ligands as competitors. Additionally, the ETR mRNA expression was analyzed using quantitative real-time-PCR. RESULTS: The mRNA of ETA but not ETB receptors was significantly elevated in heart failure, whereas total ETR density analyzed by radioligand binding was significantly reduced due to ETB receptor down regulation. ETA and ETB receptor density showed poor correlation to mRNA data (spearman correlation factor: 0.43 and 0.31, respectively). VAD support had no significant impact on the density of both receptors and on mRNA expression of ETA whereas ETB mRNA increased during VAD. A meta-analysis reveals that the ETA receptor regulation in human heart failure appears to depend on non-failing hearts. CONCLUSIONS: In deteriorating hearts of patients suffering from dilated cardiomyopathy the ETA receptor density is not changed whereas the ETB receptor is down regulated. The mRNA and the proteins of ETA and ETB show a weak correlation. Non-failing hearts might influence the interpretation of ETA receptor regulation. Mechanical unloading of the failing hearts has no impact on the myocardial ETR density.
No takes yet. Share an insight, caveat, or question.
Gärtner et al. (2017) studied this question.