Answers are grounded in this paper and cite their sources.
The dependence of the critical layer thickness hc on mole fraction x of Si1−xGex/Si heterostructures is determined by direct observations of misfit dislocations by using the electron beam induced current (EBIC) technique and transmission electron microscopy (TEM). The EBIC images of the Si1−xGex/Si interfaces show square-grid patterns running in the 〈110〉 directions. These patterns are identified by TEM observation to be misfit dislocations generated at the Si1−xGex/Si interface. The dependence of hc on x is compared with the results reported by R. People and J. C. Bean [Appl. Phys. Lett. 47, 322 (1985) and 49, 229 (1986)]. The comparison reveals that inconsistency exists between them, especially in the range of x<0.3. This inconsistency is considered to arise from the difference in the techniques adopted to determine the hc’s.
No takes yet. Share an insight, caveat, or question.
Kohama et al. (1988) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: