Why the study?
What are the mortality and thromboembolic complication rates following mitral valve replacement with different models of ball valve prostheses?
Population
Patients undergoing isolated or multiple mitral valve replacement with ball valve prostheses over a decade.
Design
Cohort
Follow-up
Up to a decade
Authors
Loading...
May support cloth-covered designs for lower thromboembolism risk; extends early prosthesis data but warrants modern validation.
What are the mortality and thromboembolic complication rates following mitral valve replacement with different models of ball valve prostheses?
Improvements in ball valve prosthesis design, particularly the development of totally cloth-covered models, significantly reduced the incidence of thromboembolic complications after mitral valve replacement.
Albert Starr (1971) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: