Key result
Biphasic waveforms achieve successful defibrillation at ~42% lower energy than monophasic waveforms in preclinical models.
Why the study?
Little work has been done measuring transthoracic defibrillation efficacy after long durations of ventricular fibrillation, especially comparing monophasic and biphasic waveforms.
Does a biphasic waveform improve defibrillation efficacy compared to a monophasic waveform after short and long durations of ventricular fibrillation in a dog model?
Does a biphasic waveform improve defibrillation efficacy compared to a monophasic waveform after short and long durations of ventricular fibrillation in a dog model?
Biphasic waveforms, particularly quasi-sinusoidal, are more efficacious than monophasic waveforms for transthoracic defibrillation after both short and long durations of ventricular fibrillation in an animal model.
Answers are grounded in this paper and cite their sources.
May guide defibrillator waveform development; hypothesis-generating in animals and leaves human translation open.
Background —Recently, interest has arisen in using biphasic waveforms for external defibrillation. Little work has been done, however, in measuring transthoracic defibrillation efficacy after long periods of ventricular fibrillation. In protocol 1, we compared the efficacy of a quasi-sinusoidal biphasic waveform (QSBW), a truncated exponential biphasic waveform (TEBW), and a critically damped sinusoidal monophasic waveform (CDSMW) after 15 seconds of fibrillation. In protocol 2, we compared the efficacy of the more efficacious biphasic waveform from protocol 1, QSBW, with CDSMW after 15 seconds and 5 minutes of fibrillation. Methods and Results —In protocol 1, 50% success levels, ED 50 , were measured after 15 seconds of fibrillation for the 3 waveforms in 6 dogs. In protocol 2, defibrillation thresholds were measured for QSBW and CDSMW after 15 seconds of fibrillation and after 3 minutes of unsupported fibrillation followed by 2 minutes of fibrillation with femoral-femoral cross-circulation. In protocol 1, QSBW had a lower ED 50 , 16.0±4.9 J, than TEBW, 20.3±4.4 J, or CDSMW, 27.4±6.0 J. In protocol 2, QSBW had a lower defibrillation threshold after 15 seconds, 38±10 J, and after 5 minutes, 41.5±5 J, than CDSMW after 15 seconds, 54±19 J, and 5 minutes, 80±30 J, of fibrillation. The defibrillation threshold remained statistically the same for QSBW for the 2 fibrillation durations but rose significantly for CDSMW. Conclusions —In this animal model of sudden death and resuscitation, these 2 biphasic waveforms are more efficacious than the CDSMW at short durations of fibrillation. Furthermore, the QSBW is even more efficacious than the CDSMW at longer durations of fibrillation.
No takes yet. Share an insight, caveat, or question.
Walcott et al. (1998) studied Ventricular fibrillation (n=6). Quasi-sinusoidal and truncated exponential biphasic waveforms vs. Critically damped sinusoidal monophasic waveform was evaluated on 50% success level (ED50) for defibrillation after 15 seconds of fibrillation. Quasi-sinusoidal biphasic waveforms achieved 50% defibrillation success at a lower energy than monophasic waveforms after 15 seconds of fibrillation in dogs.
Synapse has enriched 10 related papers. Consider them for comparative context: