Why the study?
Does an asymmetrical biphasic waveform reduce defibrillation threshold compared to a monophasic waveform in isolated rabbit hearts at varying fibrillation durations?
Does an asymmetrical biphasic waveform reduce defibrillation threshold compared to a monophasic waveform in isolated rabbit hearts at varying fibrillation durations?
Biphasic defibrillation waveforms demonstrate lower voltage and energy thresholds than monophasic waveforms in a rabbit model, with the relative advantage increasing as fibrillation duration lengthens.
Answers are grounded in this paper and cite their sources.
Animal findings extend biphasic advantage to longer fibrillation; leaves open human translation.
Biphasic waveforms reduce defibrillation threshold compared with corresponding monophasic waveforms. However, effects of fibrillation duration on relative efficacy of monophasic and biphasic waveforms are unknown. This study used a newly developed defibrillation model, the isolated right- and left-sided working rabbit heart, with epicardial defibrillation electrodes, to compare threshold for a monophasic waveform (5 msec rectangular) and an asymmetrical biphasic waveform (5 msec each pulse, V2 = 50% V1). Mean voltage defibrillation threshold (V50) was determined from sigmoidal probability of successful defibrillation versus shock intensity curves after 5, 15, and 30 seconds of fibrillation in a paired study with 10 hearts. Results showed that biphasic waveforms had significantly lower voltage and energy thresholds at all fibrillation durations and that their relative efficacy improved with increasing fibrillation duration. Biphasic voltage threshold was 38.2 +/- 2.2, 44.7 +/- 4.8, and 46.6 +/- 3.2 V after 5, 15, and 30 seconds of fibrillation compared with monophasic thresholds of 51.7 +/- 4.4 (p less than 0.002), 63.0 +/- 7.6 (p less than 0.05), and 72.1 +/- 3.9 V (p less than 0.005). Biphasic waveform energy threshold was 0.67 that for the monophasic waveform after 5 seconds of fibrillation (0.12 +/- 0.01 versus 0.18 +/- 0.03 J, p less than 0.05). The ratio between biphasic waveform threshold and monophasic waveform threshold (B/M) decreased to 0.62 at 15 seconds. At 30 seconds, B/M was 0.52 (0.17 +/- 0.02 versus 0.33 +/- 0.04 J, p less than 0.02). This study also showed that biphasic waveform threshold was a nonlinear function of monophasic waveform threshold so that improved biphasic defibrillator waveform efficacy was greatest for hearts having higher monophasic thresholds.(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Jones et al. (1990) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: