January 1, 2001Peritoneal Dialysis International

Ambulatory nighttime systolic BP load > 30% had an independent association with LVH, and CCPD patients had a higher left ventricular mass index (LVMI) than CAPD patients.

View Full Paper
Ask AI
Bookmark
Share

Why the study?

Does continuous cyclic peritoneal dialysis (CCPD) compared to continuous ambulatory peritoneal dialysis (CAPD) affect left ventricular mass index in uremic patients?

Population

32 uremic patients on maintenance peritoneal dialysis therapy without anatomical heart disease or history of…

Comparison

Continuous cyclic peritoneal dialysis (CCPD) vs Continuous ambulatory peritoneal dialysis (CAPD)

Design

Cross-sectional, nonrandomized, open

Authors

MWMingcheng WangCTChin‐Chung TsengWTWei‐Chuan Tsai

Discussion

Loading...

Member takes

Overview

Supports targeting nighttime BP load in PD patients; leaves open whether CCPD increases LV mass versus CAPD.

Structured PICO

Does continuous cyclic peritoneal dialysis (CCPD) compared to continuous ambulatory peritoneal dialysis (CAPD) affect left ventricular mass index in uremic patients?

P
Population
32 uremic patients on maintenance peritoneal dialysis (PD) therapy (22 on continuous ambulatory PD [CAPD], and 10 on continuous cyclic PD [CCPD]) without anatomical heart disease or history of receiving long-term hemodialysis.
I
Intervention
Continuous cyclic peritoneal dialysis (CCPD)
C
Comparator
Continuous ambulatory peritoneal dialysis (CAPD)
O
Outcome
Independent determinant for left ventricular hypertrophy (LVH) and differences in clinical and cardiovascular characteristics (including left ventricular mass index) between CAPD and CCPD patientssurrogate

In peritoneal dialysis patients, ambulatory nighttime systolic BP load >30% is independently associated with left ventricular hypertrophy, and CCPD is associated with higher LV mass index compared to CAPD.

Cite This Study

Wang et al. (2001) studied this question.

synapsesocial.com/papers/6a8be36971fd1aba2c8b9550https://doi.org/10.1177/089686080102100106
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Left Ventricular Hypertrophy and Blood Pressure Control in Automated and Continuous Ambulatory Peritoneal Dialysis Patients2014 · 26 citations
  2. 2Comparison of Blood Pressure Control and Left Ventricular Hypertrophy in Patients on Continuous Ambulatory Peritoneal Dialysis (CAPD) and Automated Peritoneal Dialysis (APD)2011 · 14 citations
  3. 3Hypertension and Left Ventricular Hypertrophy in Pediatric Peritoneal Dialysis Patients: Ambulatory Blood Pressure Monitoring and Echocardiographic Evaluation2006 · 20 citations
  4. 4Blood Pressure Control and Left Ventricular Hypertrophy in Long-Term Capd and Hemodialysis Patients: A Cross-Sectional Study2003 · 34 citations
  5. 5The Association of Peritoneal Transport Properties with 24-Hour Blood Pressure Levels in Capd Patients2003 · 37 citations