Why the study?
As TAVR evolves, physicians aim to simplify and streamline the procedure using minimalist approaches; this study investigated the safety and efficacy of ACURATE neo TAVR facilitated by predilatation with the nonocclusive TrueFlow balloon catheter.
Does predilatation with the TrueFlow nonocclusive balloon catheter without rapid pacing improve procedural outcomes compared to standard balloon with rapid pacing in patients undergoing TAVR?
Does predilatation with the TrueFlow nonocclusive balloon catheter without rapid pacing improve procedural outcomes compared to standard balloon with rapid pacing in patients undergoing TAVR?
Answers are grounded in this paper and cite their sources.
The TrueFlow nonocclusive balloon catheter simplifies ACURATE neo TAVR by eliminating the need for rapid pacing and provisional pacemakers in low-risk patients, reducing procedural time and postdilatation needs.
OBJECTIVES: This study aimed to investigate the safety and efficacy of ACURATE neo transcatheter aortic valve replacement (TAVR) facilitated by predilatation with the nonocclusive TrueFlow balloon catheter. BACKGROUND: Now that TAVR is moving forward, physicians have attempted to simplify and streamline the procedure and the so-called minimalist approach has become more popular. METHODS: We enrolled 142 patients (mean age: 82 ± 5 years, 61% female) in a prospective registry. Patients at low risk for intraprocedural third-degree atrioventricular block (AVB) underwent TAVR with the TrueFlow balloon without rapid pacing and without insertion of a provisional pacemaker (n = 121). The remaining 21 patients were predilated with rapid pacing using a provisional pacemaker and a standard balloon. RESULTS: Predilatation with the TrueFlow balloon was successful in all 121 patients. Postdilatation was less frequently required after predilatation with the TrueFlow (25% vs. 57%, p = .003). Moreover, median procedural duration with the TrueFlow was significantly shorter (42 [interquartile range, IQR: 34-53] vs. 55 [IQR: 46-61] min, p = .004). In-hospital outcomes were similar. At 30 days, there was no mortality, two (1%) patients had suffered a stroke and only four (3%) had required implantation of a new pacemaker. CONCLUSION: Among patients with a low risk for intraprocedural third-degree AVB, the TrueFlow nonocclusive balloon catheter facilitates implantation of the ACURATE neo without the necessity of rapid pacing and a provisional pacemaker.
No takes yet. Share an insight, caveat, or question.
Toggweiler et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: