Answers are grounded in this paper and cite their sources.
In the course of a collaborative programme on the dosimetry of neutrons with energies between 15 and 60 MeV the authors have revised calculated kerma factors and compared these with some recently published experimental measurements on neutron-induced charged particles in carbon, nitrogen and oxygen (T.S. Subramanian et al., 1980). The present authors' computed kerma factors agree best with the lowest of the wide range of values obtained by previous workers. The present calculations are believed by the authors to constitute an advance on the published work of others.
No takes yet. Share an insight, caveat, or question.
Behrooz et al. (1981) studied this question.