Key result
The Heartech left ventricular partitioning device significantly improved left ventricular ejection fraction from 32.47% at baseline to 42.5% at 1 year (p=0.001) in patients with heart failure post-MI.
Why the study?
Following safety and efficacy confirmation at 1 month post-implantation, longer-term 1-year echocardiographic outcomes of the Heartech left ventricular partitioning device in patients with chronic heart failure post-myocardial infarction needed evaluation.
Does the Heartech® left ventricular partitioning device improve echocardiographic parameters in patients with chronic heart failure post-myocardial infarction?
Observational (n=15)
Yes
Does the Heartech® left ventricular partitioning device improve echocardiographic parameters in patients with chronic heart failure post-myocardial infarction?
Answers are grounded in this paper and cite their sources.
The Heartech® left ventricular partitioning device significantly improves left ventricular systolic function and reduces ventricular volumes at 1 year in patients with chronic heart failure post-myocardial infarction.
OBJECTIVES: This study presents 1-year follow-up data of echocardiographic outcomes in patients who received the Heartech® left ventricular (LV) partitioning device (LVPD) (Xinrui Medical Equipment Co. Ltd., Shanghai, China). BACKGROUND: Our first-in-man study of the Heartech® LVPD confirmed its safety and efficacy in patients with chronic heart failure (HF) post-myocardial infarction (MI) 1 month post-implantation. This subsequent study reports the echocardiographic outcomes of these patients at 1 year of follow-up. METHODS: Fifteen patients with HF post-MI from three cardiac intervention centers in China were successfully implanted with the Heartech® LVPD via percutaneous ventricular restoration procedures. Echocardiographic parameters-including LV systolic function, diastolic function, two-dimensional speckle-tracking analysis, and right ventricular systolic function-were obtained before device implantation and at 1 month and 1 year postoperatively. RESULTS: There was no deterioration of LV diastolic function, specific strain parameters, or right ventricular function at 1 year. Relative to the echocardiographic parameters recorded before the procedure, the LV ejection fraction (32.47 ± 6.98% vs. 42.5 ± 7.41%; p = .001) was significantly improved at 1 year, while the LV end-diastolic volume index (106.29 ± 28.01 vs. 83.30 ± 31.71; p = .005) and end-systolic volume index were significantly reduced (72.47 ± 22.77 vs. 50.00 ± 19.70; p = .001). CONCLUSIONS: One-year echocardiographic follow-up results confirmed that no deterioration of LV diastolic function or specific strain parameters was observed and LV systolic function was significantly improved in patients with HF post-MI who were implanted with the Heartech® LVPD.
No takes yet. Share an insight, caveat, or question.
Su et al. (2021) conducted an observational in Chronic heart failure post-myocardial infarction (n=15). Heartech® left ventricular partitioning device vs. Baseline (pre-procedure) was evaluated on Left ventricular ejection fraction (p=0.001). The Heartech left ventricular partitioning device significantly improved left ventricular ejection fraction from 32.47% at baseline to 42.5% at 1 year (p=0.001) in patients with heart failure post-MI.