Key result
Propofol decreased systolic blood pressure compared to etomidate by reducing cardiac output and causing vasodilatation during ICD testing.
Why the study?
Does propofol compared to etomidate alter haemodynamic parameters in patients undergoing implantable cardioverter-defibrillator testing?
RCT (n=63)
Randomly assigned
No
Does propofol compared to etomidate alter haemodynamic parameters in patients undergoing implantable cardioverter-defibrillator testing?
Propofol causes more pronounced haemodynamic depression (decreased blood pressure, cardiac output, and vasodilatation) than etomidate during ICD testing, though both agents are generally well tolerated.
Answers are grounded in this paper and cite their sources.
Alerts clinicians to greater hypotension risk with propofol during ICD testing; confirms etomidate's hemodynamic advantage in this RCT.
BACKGROUND: Anaesthetic drugs and internal electrical shock may alter the haemodynamic status of patients undergoing implantable cardioverter-defibrillator (ICD) testing. Comparative data on the mechanisms of etomidate and propofol-induced changes in haemodynamic parameters are inconsistent. Also the effects of ICD shock on haemodynamics have not been extensively studied. AIM: To compare the haemodynamic effects of etomidate and propofol as well as electrical shock during ICD testing in a prospective, randomised trial. METHODS: The study group consisted of 63 consecutive patients (mean age 66 ± 10 years, 51 males) who underwent ICD testing. Haemodynamic parameters were measured using impedance cardiography (Task Force Monitor Systems, CNSystems, Austria) before and after injection of etomidate (n = 30) or propofol (n = 33) as well as immediately after internal defibrillation of ventricular fibrillation (VF). Parameters measured included heart rate, systolic (sBP), diastolic (dBP) and mean (mBP) blood pressure, stroke volume (SV), cardiac output (CO) and total peripheral resistance (TPR). RESULTS: Propofol significantly decreased the values of all measured parameters (sBP: 123.4 ± 17.1 vs. 106.3 ± 18 mm Hg, p < 0.0001; dBP: 83.7 ± 12.2 vs. 74.1 ± 13.8 mm Hg, p < 0.0001; mBP: 93.9 ± 13.1 vs. 81.1 ± 16.1 mm Hg, p < 0.0001; SV: 61.1 ± 19.3 vs. 56.4 ± 15.7 mL, p < 0.003; CO: 4.51 ± 1.07 vs. 4.17 ± 0.73 L/min, p < 0.003; and TPR: 1,735.8 ± 532.6 vs. 1,573.9 ± 390.5 dyn×s/cm⁵), whereas the only significant change following etomidate infusion was a decrease in SV (60.6 ± 11 vs. 56.8 ± 10 mL, p < 0.022). The propofol-induced changes were similar in patients with reduced (< 40%) vs. preserved (≥ 40%) left ventricular ejection fraction (LVEF) and in patients in heart failure NYHA class 0-II vs. class III-IV. Induction of VF and internal electrical shock did not cause major haemodynamic changes apart from significant, albeit very modest, drops in dBP and mBP (77 ± 2 vs. 72.9 ± 18 mm Hg, p < 0.002, and 85.2 ± 17 vs. 81.8 ± 20 mm Hg, p < 0.017, respectively). There were no complications during ICD testing. CONCLUSIONS: Propofol significantly decreased BP probably by both reducing CO and causing vasodilatation, whereas etomidate only slightly decreased dBP and mBP without affecting other parameters. Propofol-induced changes were independent of LVEF or NYHA class. Induction of VF and internal defibrillation did not cause clinically significant changes apart from very modest drops in dBP and mBP values.
No takes yet. Share an insight, caveat, or question.
Zgoła et al. (2014) conducted an RCT in Implantable cardioverter-defibrillator (ICD) testing (n=63). Propofol vs. Etomidate (target dose of 0.3-0.4 mg/kg) was evaluated on Change in systolic blood pressure (Δ sBP) in mm Hg (p=0.001). Propofol decreased systolic blood pressure compared to etomidate by reducing cardiac output and causing vasodilatation during ICD testing.