A heat-flow meter is described having the form of a small disk of tellurium-silver alloy with copper-gauze coating on its two sides. This is placed with its plane at right angles to the flow of heat to be measured, creating a small proportionate difference of temperature between the two sides. The output of the disk is 2.0 μV. for a flow of 1 B.TH.U./ft. 2 /hr. The internal resistance including leads is 1 ω. The disk is connected by fine wires through a terminal block some distance away to a galvanometer which registers the thermo-e.m.f. due to the difference in temperature of the two tellurium-copper junctions. The disk is calibrated by placing it in a measured heat-flow through a number of layers of plush. Experiments carried out in a room-size steel-walled chamber with one or more of its walls heated gave an approximately correct figure for the heat imparted to the injected air current, the volume and change of temperature of which were measured.