PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 1, 1993Arteriosclerosis and Thrombosis A Journal of Vascular Biology324 citations

Ultrasonic-pathological comparison of the human arterial wall. Verification of intima-media thickness.

View Full Paper
JEJ EdelsteinHershey (United States)JWJerome S. WollmanVA Greater Los Angeles Healthcare SystemMBM. Gene BondGeneral / Preventive / Lipids

Structured PICO

Does sonographic measurement accurately reflect histological intima-media thickness in human arterial segments?

P
Population
Human carotid and femoral arterial segments
I
Intervention
Sonographic measurement using a 7-MHz linear-array vascular transducer
C
Comparator
Histological measurement
O
Outcome
Intima-media thicknesssurrogate

Standard transcutaneous ultrasonography accurately measures far-wall intima-media thickness but is limited by axial resolution for individual tunica dimensions.

Abstract

Recent intravascular ultrasound experience challenges the accuracy of ultrasonic measurement of arterial wall thickness. We reevaluated the correlation between histological and sonographic measurements of intima-media thickness using standard transcutaneous vascular technology. Carotid and femoral arterial segments were imaged before and after fixation using a 7-MHz linear-array vascular transducer. Log compression and beam orientation were varied. Mean intima, media, and adventitia thicknesses were measured and compared with corresponding histological tunica. Tissue processing caused 2.5% shrinkage. Intraobserver reading error was 0.7% for histology and 5.4% for sonography. Ultrasound overestimated the thickness of the intima and adventitia and underestimated the thickness of the media. For combined intima-media thickness, the differences between histology and imaging were insignificant, averaging 4% for the carotid artery and 9% for the femoral artery in the far-wall projection. In the near-wall projection, sonographic intima-media thickness was 20% less than that determined histologically. We conclude that ultrasonography is limited mainly by axial resolution in quantifying the dimensions of individual arterial tunica but is capable of accurately measuring far-wall intima-media thickness.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Edelstein et al. (1993) studied this question.

synapsesocial.com/papers/6a911ad3c27f1af0e592e0c9https://doi.org/10.1161/01.atv.13.4.482
Ask AI
Helpful
Bookmark
Share
View Full Paper