Why the study?
Does the method of blood pressure measurement (sequential vs simultaneous, manual vs automated, single vs multiple) affect the magnitude of inter-arm difference?
Does the method of blood pressure measurement (sequential vs simultaneous, manual vs automated, single vs multiple) affect the magnitude of inter-arm difference?
Blood pressure measurement methodology significantly influences inter-arm difference results, with simultaneous, automated, and multiple readings recommended to prevent overestimation.
Answers are grounded in this paper and cite their sources.
Use simultaneous automated multiple readings to avoid overestimating inter-arm differences; extends evidence for standardized protocols in practice and trials.
BACKGROUND: Screening for inter-arm difference (IAD) of blood pressure (BP) at each first visit is recommended by numerous guidelines whereas it is unclear whether the method by which IAD is measured has significant influence on the IAD value. METHODS: A systematic review is made of the studies reporting on double-arm measurements and the association of IAD with procedure characteristics (Medline/PubMed, Embase, and Cochrane Library). RESULTS: The mean absolute IAD was 5.4 ± 1.7 and 3.6 ± 1.2 mm Hg for systolic and diastolic BP, respectively. Of all subjects 14% had a systolic IAD ≥10 mm Hg, 4% a systolic IAD ≥20 mm Hg, and 7% a diastolic IAD ≥10 mm Hg. The relative risk (RR) of obtaining a systolic IAD ≥10 and 20 mm Hg and a diastolic IAD ≥10 mm Hg is higher when measuring sequentially instead of simultaneously (2.2 (95% CI: 1.4-3.6), P < 0.01; 4.8 (95% CI: 1.1-21.9), P < 0.05 and 2.5 (95% CI: 1.0-6.3) P < 0.05, respectively), when using a manual instead of an automated device (2.1 (95% CI: 1.1-3.9), P < 0.05; 4.4 (95% CI: 1.8-10.8), P < 0.01 and 3.7 (95% CI: 1.6-8.6), P < 0.01, respectively) and when performing only one BP measurement instead of multiple (2.0 (95% CI: 1.1-3.8), P < 0.05; 4.3 (95% CI: 1.6-11.4), P < 0.01 and 4.4 (95% CI: 1.7-11.4), P < 0.01, respectively). CONCLUSION: Screening for IAD of BP is important but the measurement methodology has a major influence on IAD results. To prevent overestimation and observer bias IAD should be assessed simultaneously at both arms, with one or two automatic devices and multiple readings should be taken.
No takes yet. Share an insight, caveat, or question.
Verberk et al. (2011) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: