Key result
Simultaneous automatic BP measurement yields a ~1.2 mmHg lower absolute interarm difference versus conventional methods.
Why the study?
Does simultaneous automatic measurement provide more reproducible interarm blood pressure differences compared to conventional sequential measurement in patients with cardiovascular risk factors?
Cross-Sectional (n=118)
Yes
Does simultaneous automatic measurement provide more reproducible interarm blood pressure differences compared to conventional sequential measurement in patients with cardiovascular risk factors?
Answers are grounded in this paper and cite their sources.
Simultaneous automatic measurement of blood pressure in both arms provides smaller and more reproducible interarm differences than conventional sequential measurement.
OBJECTIVE: To compare two methods for screening interarm difference (IAD) of blood pressure. MATERIAL AND METHODS: This study compared two methods for double-arm measurements: (i) conventional measurement (CM) and (ii) simultaneous automatic measurement (SAM). A total of 118 patients with two or more cardiovascular risk factors and a mean age of 59±17 years were referred to two internal clinics. CM was taken with a validated aneroid manometer in sitting position on the right and left arm subsequently and vice versa. SAM was taken three times in sitting position using a validated automatic oscillometric device equipped with two cuffs for simultaneous double-arm measurements. RESULTS: The average absolute IAD of the conventional systolic value (4.9 mmHg) was significantly higher than the average absolute IAD of the SAM pressures averaged from two (3.7 mmHg; P<0.03) and three measurements (3.8 mmHg; P<0.05). The standard deviations of IADs were significantly higher (P<0.05) for the conventional systolic and diastolic measurements (4.1/3.1 mmHg) than for SAM averaged from two and three (3.0/2.3 and 3.2/2.6 mmHg, respectively) measurements. Differences of more than 20 mmHg for systolic pressure and/or 10 mmHg for diastolic pressures averaged from two CMs, two SAMs, and three SAMs were seen in 10 (9%), four (3%), and six (5%) patients, respectively. CONCLUSION: SAM provides smaller and more reproducible IADs than CM and therefore, most likely better estimates a patient's true IAD.
No takes yet. Share an insight, caveat, or question.
Lohmann et al. (2010) conducted a cross-sectional in Cardiovascular risk factors (n=118). Simultaneous automatic measurement (SAM) vs. Conventional measurement (CM) was evaluated on Average absolute interarm difference (IAD) of systolic blood pressure (p=<0.03). Simultaneous automatic measurement yielded a lower average absolute interarm difference in systolic blood pressure compared to conventional measurement.