Key result
The ACS digoxin immunoassay demonstrated the highest correlation with human heart receptor reactivities (r=0.96) compared to TDx, Stratus, and Magic assays.
Why the study?
Which commercially available digoxin immunoassay best parallels the true pharmacological activity of digoxin metabolites?
Which commercially available digoxin immunoassay best parallels the true pharmacological activity of digoxin metabolites?
Effect estimate: Correlation coefficient 0.96
The monoclonal antibody in the ACS digoxin assay closely mimics Na,K-ATPase in detecting digoxin and its metabolites, providing a better approximation of true pharmacological activity for therapeutic drug monitoring.
ACS assay may better reflect digoxin activity for TDM; animal data leave open clinical adoption pending human studies.
Our objective was to identify commercially available digoxin immunoassays whose cross-reactivity with digoxin metabolites paralleled the pharmacological activity of the metabolites. We measured the immunoreactivity of digoxigenin bis- and monodigitoxosides, digoxigenin, and dihydrodigoxin in four immunoassays and compared the immunoactivities with pharmacological activities from studies involving whole-animal and receptor (Na,K-ATPase)-based assays. Correlation coefficients for comparisons of immunoassay reactivity and human heart receptor reactivities were: ACS, 0.96; TDx, 0.60; Stratus, 0.57; and Magic, 0.42. Comparison with other biological assays showed a similar trend. The major difference in metabolite cross-reactivities among the immunoassays was that of digoxigenin (ACS, 0.7%; TDx, 103%; Stratus, 108%; Magic, 153%), which has approximately 10% bioactivity relative to digoxin. Measured recovery of mixtures of digoxin and metabolites confirmed these findings. We conclude that the monoclonal antibody in the ACS digoxin assay closely mimics Na,K-ATPase in detecting digoxin and its metabolites. This finding provides a basis for developing therapeutic drug monitoring immunoassays capable of approximating the true pharmacological activity of a mixture of drug metabolites.
No takes yet. Share an insight, caveat, or question.
Miller et al. (1994) studied this question. ACS digoxin immunoassay vs. TDx, Stratus, and Magic immunoassays was evaluated on Correlation of immunoassay reactivity and human heart receptor reactivities (Correlation coefficient 0.96). The ACS digoxin immunoassay demonstrated the highest correlation with human heart receptor reactivities (r=0.96) compared to TDx, Stratus, and Magic assays.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: