Key result
Tricuspid transcatheter edge-to-edge repair with the TriClip implant reduced TR to moderate or less in 60% of patients at 2 years and reduced all-cause hospitalization by 49% (P<0.0001).
Why the study?
TR is a common, progressive valve disease with significant mortality and hospitalization burden, and tricuspid transcatheter edge-to-edge repair offers a treatment option for high-risk patients.
Does tricuspid transcatheter edge-to-edge repair with the TriClip implant reduce tricuspid regurgitation and improve clinical outcomes in patients with symptomatic moderate or greater tricuspid regurgitation?
Does tricuspid transcatheter edge-to-edge repair with the TriClip implant reduce tricuspid regurgitation and improve clinical outcomes in patients with symptomatic moderate or greater tricuspid regurgitation?
Transcatheter edge-to-edge repair for tricuspid regurgitation using the TriClip implant provides durable TR reduction and significantly decreases all-cause hospitalizations at 2 years.
May reduce hospitalizations in symptomatic TR; leaves open confirmation versus medical therapy in randomized trials.
BACKGROUND: Tricuspid regurgitation (TR) is a common and progressive valve disease with significant mortality and hospitalization burden. Tricuspid transcatheter edge-to-edge repair provides a treatment option for high-risk patients with primary and secondary TR. METHODS: The TRILUMINATE trial ([Trial to Evaluate Treatment With Abbott Transcatheter Clip Repair System in Patients With Moderate or Greater Tricuspid Regurgitation]; n=85) is an international, prospective, single-arm, multicenter study to investigate the safety and performance of tricuspid transcatheter edge-to-edge repair with the TriClip implant in patients with symptomatic moderate or greater TR. Echocardiographic assessment was performed at a core laboratory. Outcomes included safety and clinical effectiveness and echocardiographic assessment of TR. RESULTS: At 2 years, TR was reduced to moderate or less in 60% of subjects, and reduction of at least 1 grade was achieved in 85.4% of subjects. TR reduction was sustained in 75% of the patients. While most metrics suggest the majority of favorable remodeling occurred within the first 30 days post-procedure, both right ventricular end diastolic diameter and tricuspid annular plane systolic excursion show signals of continued favorable remodeling through 2 years. Substantial improvements in 6-minute walking distance, New York Heart Association functional class, and Kansas City Cardiomyopathy Questionnaire score were sustained from 30 days to 2 years. Even with low rates of cardiovascular mortality (15.3%) and all-cause mortality (18.7%) noted at 2 years, all-cause hospitalization rate decreased from 1.30 events per patient-year 1 year before device implantation to 0.66 events per patient-year 2 years after the TriClip procedure, representing a reduction of 49% ( P <0.0001). CONCLUSIONS: Tricuspid transcatheter edge-to-edge repair using the TriClip implant was found to be safe and effective, with sustained benefits at 2 years in subjects with symptomatic moderate or greater TR. Repair efficacy was durable at 2 years in 75% of the patients. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03227757.
No takes yet. Share an insight, caveat, or question.
Lurz et al. (2023) studied Symptomatic moderate or greater tricuspid regurgitation (n=85). Tricuspid transcatheter edge-to-edge repair with the TriClip implant was evaluated on TR reduced to moderate or less. Tricuspid transcatheter edge-to-edge repair with the TriClip implant reduced TR to moderate or less in 60% of patients at 2 years and reduced all-cause hospitalization by 49% (P<0.0001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: